Model Number 8401
Medical Device Problem Codes Incorrect, Inadequate or Imprecise Result or Readings (1535); Low Readings (2460)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the device had a low reading and not accurate, no patient injury was reported.
 
Additional Manufacturer Narrative
The device's seal was intact.There was no physical damage on the device.The technician powered on off unit and a visual inspection of the flow rate test, carbon dioxide c02 test.The reported complaint was not verified after test the c02 function on the return monitor and the c02 reading was within specification.Ran c02 10% from a 4086 multi-parameter simulator.Low calibration was performed at 72 millimeters of mercury (mmhg).Flow rate was tested at 140 milliliter/minute (ml/min) (spec 120 plus /minus 20 ml/min.) the root cause of the reported issue could not be confirmed as the reported issue could not be replicated at the time of the device evaluation.The technician replaced internal tube kit.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BCI CAPNOGRAPHY MONITOR CAPNOCHECK II - 8400
Common Device Name
ANALYZER, GAS, CARBON-DIOXIDE, GASEOUS-PHASE
Manufacturer (Section D)
ST PAUL
1265 grey fox rd.
st. paul MN 55112
Manufacturer (Section G)
NULL
Manufacturer Contact
jim vegel
MDR Report Key16741952
Report Number3012307300-2023-04122
Device Sequence Number12357187
Product Code CCK
UDI-Device Identifier10610586036781
UDI-Public10610586036781
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K991086
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 04/14/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number8401
Device Catalogue Number8401
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/14/2021
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/09/2023
Initial Report FDA Received Date04/14/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/31/2017
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-