Catalog Number RBY2C0825
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/31/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The product was not returned for evaluation.Without the return of the device, the root cause of the problem cannot be determined.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.This report is associated with mfr report numbers: 3005168196-2023-00186, 3005168196-2023-00187, 3005168196-2023-00188, 3005168196-2023-00189, 3005168196-2023-00190.6.3005168196-2023-00192 7.3005168196-2023-00193 8.3005168196-2023-00194.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure in the subclavian artery using pod packing coils (pod pc), ruby coils, and a lantern delivery microcatheter (lantern).During the procedure, the physician placed three pod pcs in target vessel using the lantern.It was reported that after placing the three pod pcs, the physician noticed the distal end and midshaft of the lantern was kinked by the coil compaction.Therefore, the lantern was removed.The physician then inserted a new lantern in the target location and advanced additional pod pcs and ruby coils into the vessel.Subsequently, the physician pulled back on the lantern to be removed and noticed all of the previously placed pod pcs and ruby coils that were implanted had migrated from the subclavian artery to the brachial artery under fluoroscopy.The lantern was removed, and the physician performed a cutdown surgery and removed the migrated pod pcs and ruby coils.The procedure had ended at this point.There was no report of an adverse effect to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RUBY COIL
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key16797269
Report Number3005168196-2023-00191
Device Sequence Number16928822
Product Code HCG
UDI-Device Identifier00814548018850
UDI-Public814548018850
Combination Product (Y/N)N
Initial Reporter StateOK
Initial Reporter CountryUS
PMA/510(K) Number
K170852
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/24/2023
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberRBY2C0825
Device Lot NumberF00004997
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/31/2023
Initial Report FDA Received Date04/24/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/23/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexMale
Date Report Sent to FDA01/01/2005
-
-