Model Number IPN041700
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/05/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that "the doctor found cuff leakage when doing clinical setting before using on patient.Then changed new one, no impact on patient".
 
Additional Manufacturer Narrative
Qn# (b)(4).
 
Event or Problem Description
It was reported that "the doctor found cuff leakage when doing clinical setting before using on patient.Then changed new one, no impact on patient".
 
Additional Manufacturer Narrative
(b)(4).The actual sample was returned for evaluation.A visual exam was performed and a stain was observed indicating the sample could have been used by the customer.The pressure of the clear cuff and the blue cuff of the device were then tested by inflating the cuffs to 25 mbar using a calibrated endotest.It was observed that the blue cuff was able to maintain pressure at 25mbar; however, the clear cuff would not stay inflated.A water leak test was then conducted on the returned sample by immersing it underwater.Bubbles were observed flowing out from the clear cuff indicating a leak.The area of leakage was observed under magnification and cut marks were observed on the cuff.A device history record review was performed and no relevant findings were identified.The complaint of leakage was confirmed; however, a root cause for the issue could not be determined.There is a 100% inflation and water leak test conducted at the manufacturing facility whereby any leakage would be detected prior to release.It is possible that the failure could be induced during product handling by the user, although this could not be confirmed.Other remarks: n/a.Corrected data: n/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RUSCH DOUBLE LUMEN BRONCHIAL TUBE SET LEFT
Common Device Name
TUBE, BRONCHIAL (W/WO CONNECT
Manufacturer (Section D)
TELEFLEX MEDICAL
athlone
Manufacturer (Section G)
TELEFLEX MEDICAL SDN. BHD.
lot no : pt2577 jalen perusahaan
4 kamunting industrial estate
perak, west malaysia 34600
MY   34600
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key16809828
Report Number8040412-2023-00195
Device Sequence Number12260190
Product Code BTS
UDI-Device Identifier14026704344229
UDI-Public14026704344229
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K951091
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/06/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIPN041700
Device Catalogue Number116100-000350
Device Lot NumberKME22J0131
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/06/2023
Supplement Date Received by Manufacturer06/02/2023
Initial Report FDA Received Date04/25/2023
Supplement Report FDA Received Date06/02/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/05/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-