| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/11/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and is pending evaluation.Results are expected soon.
|
| |
|
Event or Problem Description
|
|
It was reported that the customer is having an issue with item 3274355.Per the rn, blood noted to be leaking from the catheter right where it meets the securement wings.Clear and obvious leak observed.Additional information: the event did not occur during an urgent or life-threatening medical situation.Tpn infusion was interrupted but no adverse outcome was reported.The catheter was secured with statlock.
|
| |
|
Event or Problem Description
|
|
It was reported that the customer is having an issue with item 3274355.Per the rn, blood noted to be leaking from the catheter right where it meets the securement wings.Clear and obvious leak observed.Additional information: the event did not occur during an urgent or life-threatening medical situation.Tpn infusion was interrupted but no adverse outcome was reported.The catheter was secured with statlock.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a leaking catheter was confirmed.The product returned for evaluation was one 4 fr d/l powerpicc sv.The investigation findings are consistent with damage accumulated through flexural fatigue.Flexural fatigue occurs due to cyclic kinking of the catheter tube in which physiological, placement, usage, and mechanical factors may gradually form a crack(s) in the catheter.The returned product sample was evaluated and a split was observed just distal of the molded suture wing.The catheter split contained physical features associated with material fatigue, and the characteristics observed which supported this type of failure included: ¿ damage which was circumferentially aligned ¿ fracture edges which were rounded and polished due to repeated material wear ¿ 'c' shaped impressions leading into the fracture site which are consistent with material buckling due to movement which caused the fracture edges to be pressed together ¿ overall elliptical shape to the fracture cross-section (a result of repeated kinking of the tubing) an examination of the catheter structure revealed no potential damage/defect related to manufacture of the product.The damage location suggested that catheter securement, access and maintenance techniques may have contributed.H3 other text : evaluation findings are in section h.11.
|
| |
|