SHIRAKAWA OLYMPUS CO., LTD. ENDOCAPSULE SMALL INTESTINAL CAPSULE ENDOSCOPE SET Back to Search Results
Model Number MAJ-2027
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Gastrointestinal Problem (4491)
Date of Event 04/09/2021
Type of Reportable Event Serious Injury
Event or Problem Description
Olympus reviewed the following literature titled, "feasibility and diagnostic yield of small-bowel capsule endoscopy in patients with surgically altered gastric anatomy: the saga study." background: little is known about small-bowel (sb) capsule endoscopy (ce) in patients with a history of gastric surgery.This study aims to evaluate the feasibility and diagnostic yield (dy) of orally ingested sb-ce in patients with surgically altered gastric anatomy.Methods: twenty-four european centers retrospectively identified patients who had sb-ce after total or subtotal gastrectomy.The primary outcome was the dy of sb-ce (intermediate p1 to highly p2 relevant findings).Secondary outcomes were gastric and sb transit times, completion, cleanliness, and adverse event rates.Results: studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (billroth i, 13.1%; billroth ii, 34.6%), total gastrectomy (7.4%), whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%).Obscure gi bleeding was the most frequent indication (85.1%).Sb completion rate was 84.3%.One capsule retention in the sb was noted (adverse event rate,.4%).Median sb transit time was 286 minutes (interquartile range [235; 387]).Cleanliness was rated as adequate in 92.1% of procedures.After exclusion of abnormalities found at the upper anastomotic site, the dy was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%).Conclusions: sb-ce seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high dy.The spectrum of abnormal sb findings in these patients may be different from what is known from the literature in nonoperated patients.(gastrointest endosc 2021;94:589-97.) type of adverse events/number of patients: asymptomatic small bowel (sb) retention - 1 patient.There is no report of any olympus device malfunction in any procedure described in this study.
 
Additional Manufacturer Narrative
The suspect device was not returned to olympus.A dhr could not be checked because the serial number of the subject device was unknown.Investigation was conducted based on the complaint information.Based on the results of the investigation, it is likely the reported event is an accident, or a complication associated with a surgical procedure using the subject device.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Olympus will continue to monitor field performance for this device.The literature article is attached to this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDOCAPSULE SMALL INTESTINAL CAPSULE ENDOSCOPE SET
Common Device Name
ENDOCAPSULE SMALL INTESTINAL CAPSULE ENDOSCOPE SET
Manufacturer (Section D)
SHIRAKAWA OLYMPUS CO., LTD.
3-1 okamiyama
odakura, nishigo-mura,
nishishirakawa-gun, fukushima 961-8 061
JA  961-8061
Manufacturer (Section G)
SHIRAKAWA OLYMPUS CO., LTD.
3-1 okamiyama
odakura, nishigo-mura,
nishishirakawa-gun, fukushima 961-8 061
JA   961-8061
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key16850267
Report Number3002808148-2023-04418
Device Sequence Number6526625
Product Code NEZ
UDI-Device Identifier04953170328268
UDI-Public04953170328268
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K183053
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Study,Literature,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberMAJ-2027
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/02/2023
Initial Report FDA Received Date05/01/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NON-OLYMPUS - MIROCAM 1200; NON-OLYMPUS - MIROCAM 1600; NON-OLYMPUS - MIROCAM 2000; NON-OLYMPUS - OMOM; NON-OLYMPUS - PILLCAM COLON2; NON-OLYMPUS - PILLCAM SB2; NON-OLYMPUS - PILLCAM SB3; NON-OLYMPUS - PILLCAMSB1
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient SexUnknown
-
-