Model Number KD-655Q
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hemorrhage/Blood Loss/Bleeding (1888); Perforation (2001)
Date of Event 09/27/2021
Type of Reportable Event Serious Injury
Event or Problem Description
Olympus reviewed the following literature titled, "efficacy of single-balloon overtube for endoscopic submucosal dissection in the proximal colon: a propensity score-matched analysis".Objectives: a single-balloon overtube (sbo) can improve poor scope operability during colonic endoscopic submucosal dissection (esd).We aimed to evaluate the clinical usefulness of sbo for esd in the proximal colon and the predictive factors for cases in which sbo is useful.Methods: a total of 88 tumors located in the proximal colon resected by balloon-assisted esd (ba-esd) using sbo and 461 tumors resected by conventional esd (c-esd) between (b)(6) 2015 and (b)(6) 2020 were considered.Seventy-eight tumors each in the ba-esd and c-esd groups were matched by propensity score matching.Esd outcomes were compared between the groups, and a decision tree analysis was performed to explore the predictive factors for cases in which sbo is useful.Results: there were no significant differences between the groups in the major outcomes such as en bloc resection rate (95% vs.99%, p = 0.17), r0 resection rate (92% vs.96%, p = 0.30), mean dissection speed (16 mm2/min vs.16 mm2/min,p = 0.53), and intraoperative perforation rate (5% vs.6%,p = 0.73).Even when considering cases with poor preoperative scope operability, there were no significant differences between the groups.Comparison of tumors =40 mm in diameter between the groups confirmed that the intraoperative perforation rate was significantly lower in the ba-esd group than in the c-esd group (0% vs.24%, p = 0.0188).Conclusion: sbo is useful for esd of tumors =40 mm in diameter in the proximal colon to prevent intraoperative perforation, which usually has a long procedure time.Type of adverse events/number of patients: intraoperative perforation (ba-esd) (4 patients).Intraoperative perforation (c-esd) (5 patients).Delayed perforation (ba-esd) (1 patients).Postoperative bleeding (ba-esd) (3 patients).Postoperative bleeding (c-esd) (1 patients).Preoperative scope operability (poor) (27+249 = 266).Intraoperative scope operability (poor) (3+130 = 133).This literature article requires 9 reports.The related patient identifiers are below.The following reports are for the adverse events: (b)(6) colonoscope (pcf-q260azi).(b)(6) colonoscope (pcf-h290ti).(b)(6) standard tip hood (mh-463 as distal attachment).(b)(6) dualknife (kd-655l as single use electrosurgical knife kd-650).(b)(6) dualknife j (kd-655q as single use electrosurgical knife kd-655).(b)(6) tknife nano (kd-612q as single use electrosurgical knife kd-612).(b)(6) sbo (st-cb1).In addition, the following reports are for the "scope operability (fair)" scope malfunction.(b)(6) pcf-q260azi (iuc gib bending manipulation and insertion tube defects).(b)(6) pcf-h290ti (iuc gib bending manipulation and insertion tube defects).This medwatch report is for patient identifier (b)(6).
 
Additional Manufacturer Narrative
The suspect device has not been returned to olympus for evaluation.The investigation is in process.The literature article is attached for additional information.Once the investigation has been completed, a supplemental report will be submitted with device evaluation results.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse events cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.Olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE ELECTROSURGICAL KNIFE KD-655
Common Device Name
SINGLE USE ELECTROSURGICAL KNIFE
Manufacturer (Section D)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA  036-0357
Manufacturer (Section G)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key16855947
Report Number9614641-2023-00592
Device Sequence Number7529290
Product Code KNS
UDI-Device Identifier04953170405631
UDI-Public04953170405631
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K171158
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Study,Literature,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberKD-655Q
Device Lot NumberUNKNOWN(LITERATURE)
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/02/2023
Supplement Date Received by Manufacturer05/15/2023
Initial Report FDA Received Date05/02/2023
Supplement Report FDA Received Date05/25/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-