MAUDE Adverse Event Report: W. L. GORE & ASSOCIATES, INC. GORE® CARDIOFORM ASD OCCLUDER; TRANSCATHETER SEPTAL OCCLUDER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

W. L. GORE & ASSOCIATES, INC. GORE® CARDIOFORM ASD OCCLUDER; TRANSCATHETER SEPTAL OCCLUDER Back to Search Results
Model Number ASD37A
Medical Device Problem Code Patient Device Interaction Problem (4001)
Health Effect - Clinical Codes Atrial Flutter (1730); Thrombosis/Thrombus (4440)
Date of Event 04/28/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The gore® cardioform asd occluder instructions for use states: adverse events associated with the use of the occluder may include but are not limited to: new arrhythmia requiring treatment and thrombosis of thromboembolic event resulting in clinical sequelae.The summary of the imaging evaluation stated the following: it was reported the physician implanted a 37mm gore® cardioform asd occluder on (b)(6) 2023.At a follow-up appointment on (b)(6) 2023, a suspected thrombus was noted on the right disc.In the initial echo image 1 provided from the day of implant, the device appears to be in a stable position.Without additional imaging this cannot be confirmed.In echo image 2, a large mass can be seen on the right atrial disc.It appears that the mass is contained in the right atrial disc indicating right disc expansion but without additional imaging, this cannot be confirmed.It also cannot rule out the possibility of thrombus on the exterior of the device or a right atrial myxoma.Without additional imaging, that cannot be confirmed.The patient was treated with an unknown anticoagulant.The patient was also noted to be in atrial flutter and was treated with beta blockers.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Event or Problem Description
It was reported the physician implanted a 37mm gore® cardioform asd occluder on (b)(6) 2023.At a follow-up appointment on (b)(6) 2023, a suspected thrombus was noted on the right disc.The patient was treated with an unknown anticoagulant.The patient was also noted to be in atrial flutter, and was treated with beta blockers.
 
Event or Problem Description
It was reported the physician implanted a 37mm gore® cardioform asd occluder on (b)(6) 2023.At a follow-up appointment on (b)(6) 2023, a suspected thrombus was noted in the right disc.The patient was treated with an unknown anticoagulant.The patient was also noted to be in atrial flutter, and was treated with beta blockers.Physician update: the right disc expansion caused the right atrial eyelet to come off the locking loop.The physician is planning on surgical removal of the device unless the right disc flattens out soon.
 
Additional Manufacturer Narrative
The summary of the imaging evaluation stated the following: it was reported the physician implanted a 37mm gore® cardioform asd occluder on (b)(6) 2023.At a follow-up appointment on (b)(6) 2023, a suspected thrombus was noted on the right disc.In the initial echo image 1 provided from the day of implant, the device appears to be in a stable position.Without additional imaging this cannot be confirmed.In echo image 2, a large mass can be seen on the right atrial disc.It appears that the mass is contained in the right atrial disc indicating right disc expansion but without additional imaging, this cannot be confirmed.It also cannot rule out the possibility of thrombus on the exterior of the device or a right atrial myxoma.Without additional imaging, that cannot be confirmed.The patient was treated with an unknown anticoagulant.The patient was also noted to be in atrial flutter and was treated with beta blockers.Update: upon review of the additional fluoro images, a gore cardioform asd occluder can be visualized.In fluoro image one dated on (b)(6) 2023, a gore cardioform asd occluder can be visualized.The device has clear disc separation around the interior/posterior rim.Around the anterior/ superior rim, there is minimal disc separation between the left and right discs.On the fluoro image dated on (b)(6) 2023, the right atrial disc is elongated, and the device has become unlocked.This is indicative of right atrial disc enlargement.The tee images also confirm that the mass originally seen in the echo images 1 and two, is contained within the device.The cause for the right disc expansion cannot be determined.
 
Event or Problem Description
It was reported the physician implanted a 37mm gore® cardioform asd occluder on (b)(6)2023.At a follow-up appointment on (b)(6) 2023, a suspected thrombus was noted in the right disc.The patient was treated with an unknown anticoagulant.The patient was also noted to be in atrial flutter, and was treated with beta blockers.Physician update: the right disc expansion caused the right atrial eyelet to come off the locking loop.The device was removed and asd was closed in a surgical procedure.
 
Additional Manufacturer Narrative
B5 - updated description.D6b- added explant date.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® CARDIOFORM ASD OCCLUDER
Common Device Name
TRANSCATHETER SEPTAL OCCLUDER
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
KENDRICK PEAK MPD B/P
4250 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
dan kitterman
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key16860826
Report Number2017233-2023-03905
Device Sequence Number17497939
Product Code MLV
UDI-Device Identifier00733132636501
UDI-Public00733132636501
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
P050006
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2023
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 05/31/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/13/2024
Device Model NumberASD37A
Device Catalogue NumberASD37A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/28/2023
Supplement Date Received by Manufacturer05/04/2023
05/31/2023
Initial Report FDA Received Date05/03/2023
Supplement Report FDA Received Date05/12/2023
05/31/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/15/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age31 YR
Patient SexMale
-
-