| Model Number |
N/A |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Device name: cook spectrum minocycline/rifampin impregnated triple lumen central venous catheter tray.This report includes information known at this time.A follow-up report will be submitted should additional, relevant information become available.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned or that a death or serious injury occurred; nor is it admission that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Event or Problem Description
|
|
It was reported that the catheter from a cook spectrum minocycline/rifampin impregnated triple lumen central venous catheter tray disassembled.A pediatric critical care physician reported the central line catheters have disassembled and the hubs have cracked.Additional information regarding the event and patient outcome has been requested but is currently unavailable.This report will capture the disassembled catheter.The cracked hub will be captured in a report with patient identifier: (b)(6).
|
| |
|
Additional Manufacturer Narrative
|
|
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.Additional information: d4 - product lot #, expiration date, unique identifier; h4 this report includes information known at this time.A follow-up report will be submitted should additional, relevant information become available.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned or that a death or serious injury occurred; nor is it admission that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Event or Problem Description
|
|
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
|
| |
|
Event or Problem Description
|
|
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
|
| |
|
Additional Manufacturer Narrative
|
|
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.Investigation ¿ evaluation on 01may2023, cook became aware by university health systems (united states) of an issue involving a cook spectrum minocycline/rifampin impregnated triple lumen central venous catheter tray (rpn: c-utlmy-501j-lsc-abrm-hc-fst; lot: 15165171).It was reported the device disassembled.No other information was provided.Reviews of documentation including the complaint history, device history record (dhr), instructions for use (ifu), and quality control procedures of the complaint device were conducted during the investigation.The complaint device was not returned; therefore, no physical examinations could be performed.However, a document-based investigation evaluation was performed.A review of the device master record (dmr) concluded that sufficient inspection activities are in place to identify this failure mode prior to distribution.A review of the dhrs for the reported complaint device lot 15165171 and the related subassembly lots revealed no relevant non-conformances.A database search for complaints on the reported lot found one additional non-related complaint reported from the field.Cook also reviewed product labeling.The product ifu, [c_t_ulmabrm_rev4] ¿spectrum and spectrum glide central venous catheters,¿ provides the following information to the user related to the reported failure mode: warnings ¿do not power inject contrast medium through catheter.Catheter rupture may result.Use of 10cc or larger syringe will reduce the risk of catheter rupture.¿ precautions ¿do not cut, trim or modify catheter or components prior to placement or intraoperatively.Catheter should not be used for long-term indwelling applications.If lumen flow is impeded, do not force injection or withdrawal of fluids.Notify attending physician immediately.¿ the information provided upon review of dmr, product labeling, and dhr, does not indicate the device was manufactured out of specification.There is no evidence of nonconforming material in house or in the field.Based on the information provided, no product returned, and the results of the investigation, a definitive cause for the failure could not be established.The appropriate personnel have been notified.Cook will continue to monitor for similar complaints.Per the risk assessment no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|