ABBOTT VASCULAR GRAFTMASTER RX CORONARY STENT GRAFT SYSTEM; CORONARY STENT DELIVERY SYSTEM Back to Search Results
Model Number 1012580-16
Medical Device Problem Codes Material Separation (1562); Failure to Advance (2524); Deformation Due to Compressive Stress (2889)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/13/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Manufacturer's investigation is still pending at this time.Results and conclusions will be provided in the final report.The additional graftmaster devices referenced in b5 are filed under separate medwatch report numbers.Na.
 
Event or Problem Description
It was reported that the procedure was to treat a perforation in the mid left anterior descending artery.The 2.8x26mm graftmaster was attempted to advance; however, met resistance with the heavy calcification and failed to cross.It was noted the stent struts became flared.Three additional (2.8x16mm, 2.8x16mm, 3.5x16) graftmaster covered stent delivery systems (sds) were advanced, but all became kinked at the proximal shaft during advancement due to resistance with the anatomy.All three gfraftmaster sds separated at the proximal shaft during removal.The patient was transferred to outside facility for coronary artery bypass graft (cabg) emergent; however, was denied.Therefore, the patient returned and the perforation was coiled.There was no adverse patient sequela.No additional information was provided.
 
Additional Manufacturer Narrative
A visual, functional, and dimensional inspection was performed on the returned device.The reported deformation due to compressive stress and material separation was confirmed.The reported failure to advance could not be evaluated as the exact anatomical conditions encountered by the device used during the procedure could not be replicated in the test laboratory.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar incidents from this lot.The reported difficulties appear to be related to the operational context of the procedure.There is no indication of a product quality issue with respect to manufacture, design, or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GRAFTMASTER RX CORONARY STENT GRAFT SYSTEM
Common Device Name
CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key16886365
Report Number2024168-2023-04838
Device Sequence Number5956292
Product Code MAF
UDI-Device Identifier08717648176340
UDI-Public08717648176340
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
H000001
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2024
Device Model Number1012580-16
Device Catalogue Number1012580-16
Device Lot Number2053141
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 04/13/2023
Supplement Date Received by Manufacturer07/13/2023
Initial Report FDA Received Date05/08/2023
Supplement Report FDA Received Date08/01/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/31/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age73 YR
Patient SexFemale
Patient Weight89 KG
-
-