C.R. BARD, INC. (BASD) -3006260740 POWERPICC PROVENA 5F TL MAX BARRIER PLUS KIT; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS Back to Search Results
Model Number N/A
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/16/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and is pending evaluation.Results are expected soon.
 
Event or Problem Description
Customer reported a 5fr tl powerpicc provena inserted in the right upper arm basilic vein on (b)(6) 2023.Catheter was tpa'd in one lumen on 4/8 and one on 4/13.Catheter continued to have persistent issues with functionality.Chest x-ray was requested to assess for kink.Kink near the insertion site confirmed on 4/16.Picc was pulled back 2cm on 4/16 and kink resolved.However, picc tip is now in the upper svc and "may need replacement".Picc dwell time was 17 days.
 
Additional Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a catheter kink was confirmed but the cause is unknown.A single ap radiograph showing the patient¿s right arm was returned for evaluation.A catheter, consistent with the implicated 5fr t/l powerpicc provena, was seen in the image.Overlapping of the catheter shaft was seen in this view with a probable kink.It could not be determined from this image if the kink was located at the skin, muscle, or venous insertion site.Possible contributing factors for a kink in the catheter could include the anatomic variables, catheter placement, or catheter securement.The ifu states, ¿avoid placement or securement of the catheter where kinking may occur, to minimize stress on the catheter, patency problems or patient discomfort.¿ and ¿avoid sharp or acute angles during implantation which could compromise the patency of the catheter lumen¿.A review of the manufacture quality and inspection records for the specific lot involved found no potentially related issues encountered during the manufacture and assembly of that product lot.The report of a kinked catheter has been documented and will be monitored as part of complaint trending.H3 other text : evaluation findings are in section h.11.
 
Event or Problem Description
Customer reported a 5fr tl powerpicc provena inserted in the right upper arm basilic vein on (b)(6) 2023.Catheter was tpa'd in one lumen on (b)(6) and one on (b)(6).Catheter continued to have persistent issues with functionality.Chest x-ray was requested to assess for kink.Kink near the insertion site confirmed on (b)(6).Picc was pulled back 2cm on (b)(6) and kink resolved.However, picc tip is now in the upper svc and "may need replacement".Picc dwell time was 17 days.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POWERPICC PROVENA 5F TL MAX BARRIER PLUS KIT
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V. -9617592
blvd. montebello #1
parque industrial colonial
reynosa, tamaulipas 88780
MX   88780
Manufacturer Contact
kayla bevins
605 north 5600 west
salt lake city 84116
8015950700
MDR Report Key16915588
Report Number3006260740-2023-01824
Device Sequence Number15046887
Product Code LJS
UDI-Device Identifier00801741155178
UDI-Public(01)00801741155178
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K053501
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2023
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 07/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/30/2023
Device Model NumberN/A
Device Catalogue NumberS1385108D5
Device Lot NumberREGS0740
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/19/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/19/2023
Supplement Date Received by Manufacturer07/21/2023
Initial Report FDA Received Date05/11/2023
Supplement Report FDA Received Date07/26/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/01/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-