| Catalog Number |
8065601187 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Retinal Detachment (2047); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.Chiharu iwahashi, efficacy of inner wall retinectomy for bullous schisis cavity hanging over or threatening the macula in patients with congenital x-linked, retinoschisis.Retina.43, 64¿71, 2023.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
A physician reported via literature source regarding the surgical outcome of vitrectomy for bullous schisis cavity hanging over or threatening the macula in patients with (congenital x-linked retinoschisis) cxlrs and evaluated surgical techniques, including iwr, and the use of intraocular tamponade.The third patient in the study underwent a lens-sparing, inner wall retinectomy and gas application procedure and during the follow up it was found that the patient had developed proliferative vitreoretinopathy and rhegmatogenous retinal detachment in right eye.After a retinal tear formation which occurred temporal to the macula 3 months after the initial vitrectomy, probably because of the traction by membranes developed on the surrounding retina.The retina was reattached after two additional surgeries including lensectomy, pars plana vitrectomy (ppv), membrane peeling, encircling, and silicone oil tamponade.This is one of six reports for the third patient (od) involved in the event.
|
| |
|
Additional Manufacturer Narrative
|
|
Fda patient event code 2047 has been removed.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
There is no complication related to silicone oil.Silicone oil was used to treat a complication after it had developed.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information provided in sections h.6.And h.10.No lot code was reported by the customer; therefore, lot specific evaluation cannot be completed.All compounding, preprocessing, filling and packaging mbrs are subjected to 2 independent reviews.In addition, the following are reviewed: - all chemistry and microbial finished product results.- environmental, utility, bioburden records.- sanitization records.- sterilization cycles.Silikon 1000 is compounded by (1) chemical and thermal extraction, and (2) sterile filtration of oil prior to filling.The product is then filled into its primary packaging components using aseptic processing.Silikon 1000 10 ml glass bottles and the stoppers are made from silicone ; the product is filled on line 21.The product is terminally sterilized using dry heat.Following sterilization, units are 200% inspected for particulate in the solution and then packaged into pouches and sealed.The product insert includes the following instructions: 1) outside the sterile field, remove the silikon 1000 vial from the clear polyethylene bag and place it in a stable location.Do not shake silikon 1000.2) hold the silikon 1000 vial firmly, and remove the aluminum seal and stopper.3) within the sterile field, securely place a 20 gauge cannula on a 10 ml syringe.4) hold the vial within reach of the sterile field and aseptically introduce the cannula fitted into the syringe into the vial and withdraw the silikon 1000 taking care not to introduce air bubbles.Two persons are required for this procedure.5) after the silikon 1000 has been completely transferred into the syringe remove the 20 gauge cannula from the syringe and dispose of it properly.Securely place a new sterile cannula onto the syringe.6) the silikon 1000 is now ready to be used.The syringe may be stored temporarily within the cannula pointed upward to allow any air bubbles to come to the tip for easy removal.7) at the conclusion of the procedure properly discard the syringe and any remaining silikon 1000.Root cause for the complaint condition could not be determined.Potential root causes: ¿ solution quality issue ¿chemistry and microbiology data must meet regulatory requirements prior to release.¿ consumer mishandling - no conclusion can be made regarding the contribution of consumer mishandling as this factor is outside the control of the manufacturing facility.¿ event related to consumer physiology ¿ no conclusion can be made regarding the contribution of unique consumer physiology as this factor is outside the control of the manufacturing facility.¿ event related to surgical technique ¿ no conclusion can be made regarding the contribution of surgical technique.The product labeling for silikon 1000 provides indications for use, contraindications, warnings, precautions, and directions for use to ensure proper use of the product.Surgical technique, product handling and storage are unknown.Lot specific evaluation is not possible without the lot code being reported.No further action warranted at this time.The manufacturer internal reference number is: (b)(4).
|
| |
|
Search Alerts/Recalls
|