• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: LDR MÉDICAL ROI-A MEDIAN IMPLANT PXL : 27X30 H 12 MM 10 DEG.; ROI-A ALIF CAGE SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

LDR MÉDICAL ROI-A MEDIAN IMPLANT PXL : 27X30 H 12 MM 10 DEG.; ROI-A ALIF CAGE SYSTEM Back to Search Results
Catalog Number IR2532P
Medical Device Problem Code Crack (1135)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/20/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Without a product return, no product evaluation is able to be conducted.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.
 
Event or Problem Description
It was reported that an roi-a cage broke, allowing it to detach from implant holder while the first plate was being installed intraoperatively.The cage and plate were removed and replaced with another cage and both plates were successfully installed to complete the procedure.There was a delay of 20 minutes without patient impacts.
 
Additional Manufacturer Narrative
Additional information in h4 and h6: component, investigation type, findings, and conclusions.Device evaluation: the returned device matches the information in the complaint file and was examined.Visual inspection revealed that the cage was fractured.Root cause: a definitive root cause cannot be determined with the information provided.This event could possibly be attributed to off-axis forces applied on the cage during anchoring plate insertion.Dhr review: per dhr review, the part was likely conforming when it left zimvie control.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
 
Event or Problem Description
It was reported that an roi-a cage broke, allowing it to detach from implant holder while the first plate was being installed intraoperatively.The cage and plate were removed and replaced with another cage and both plates were successfully installed to complete the procedure.There was a delay of 20 minutes without patient impacts.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROI-A MEDIAN IMPLANT PXL : 27X30 H 12 MM 10 DEG.
Common Device Name
ROI-A ALIF CAGE SYSTEM
Manufacturer (Section D)
LDR MÉDICAL
quartier europe de l¿ouest
5, rue de berlin
sainte-savine, na 10300
FR  10300
Manufacturer (Section G)
LDR MÉDICAL
quartier europe de l¿ouest
5, rue de berlin
sainte-savine, na 10300
FR   10300
Manufacturer Contact
sabrina abla
10225 westmoor dr.
na
westminster, CO 80021
7206965158
MDR Report Key16973320
Report Number3004788213-2023-00045
Device Sequence Number6499655
Product Code MAX
UDI-Device Identifier03662663011358
UDI-Public(01)03662663011358(17)270501(10)M72880
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K153495
Exemption Number5645646
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2023
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/25/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue NumberIR2532P
Device Lot NumberM72880
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/24/2023
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date05/22/2023
Supplement Report FDA Received Date04/26/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/08/2022
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
PLATE, IR2008T LOT 289685/1
Patient SexPrefer Not To Disclose
Patient EthnicityNon Hispanic
-
-