Event or Problem Description
|
|
Intraoperatively both instruments got jammed during use.A surgical delay was not reported.No adverse patient consequences.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information, which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained, that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary: the device associated with this report was returned for analysis.Visual analysis revealed that the rod for reaming guide holder (230774002) was found stuck inside of the holder for reaming guides (230774001) causing inability to disassemble mating devices.The reported allegation can be confirmed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: dhr review was performed according to "dhr 230774001 lot 5316581" attached on notes & attachments.Product name: holder for reaming guides.Product code: 230774001.Lot number: 5315681.1) quantity manufactured: (b)(4).2) date of manufacture: 04/12/2018.3) any anomalies or deviations identified in dhr: no non-conformances associated with this lot.4) expiry date: n/a.5) ifu reference: ifu-w90966.
|
| |
|