| Model Number |
N/A |
| Medical Device Problem Codes |
Break (1069); Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/30/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and is pending evaluation.Results are expected soon.
|
| |
|
Event or Problem Description
|
|
It was reported that port a cath tubing broke at the site where tubing connects to hub.Completely broke apart.Additional information received.: the event did not occur during a life-threatening or urgent medical situation.The break was discovered during routine inspection.Normal saline was used but nothing was infusing at the time of event.Patient had to be deaccessed and reaccessed.Port access is a very stressful procedure for the pediatric population causing unnecessary distress.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a split extension tubing was confirmed and the cause is currently under investigation.The product returned for evaluation was one 20 ga powerloc max infusion set.The returned product sample was evaluated and the following observations were made: ¿ a complete break in the extension tube was confirmed and occurred at the interface of the proximal luer adapter ¿ the fracture surfaces of the damage contained striation-like patterns which were indicative of flexural fatigue based failures, which may have been a contributing factor to the extension tubing damage.Repetitive mechanical stresses such as twisting and kinking may have contributed to the observed event; however, it appeared that additional unidentified factors also contributed.The device is a supplied component and the supplier has been notified of this event.
|
| |
|
Event or Problem Description
|
|
It was reported that port a cath tubing broke at the site where tubing connects to hub.Completely broke apart.Additional information received.: the event did not occur during a life-threatening or urgent medical situation.The break was discovered during routine inspection.Normal saline was used but nothing was infusing at the time of event.Patient had to be deaccessed and reaccessed.Port access is a very stressful procedure for the pediatric population causing unnecessary distress.
|
| |
|