BOSTON SCIENTIFIC CORPORATION AMS SPECTRA CONCEALABLE PENILE PROSTHESIS; PROSTHESIS PENILE Back to Search Results
Model Number 720054-02
Medical Device Problem Code Material Discolored (1170)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/19/2023
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported, that the patient underwent a procedure.To remove the ams spectra concealable penile prosthesis, because the device was bending.The device was replaced with a tactra malleable penile prothesis.There were no patient complications reported.
 
Additional Manufacturer Narrative
Upon receipt at our quality assurance laboratory, the returned device underwent a thorough analysis.Noth cylinders were visually inspected, and functionally tested.Visual examination revealed that both cylinders had holes in the distal of their bodies with internal component exposed, consistent with explant damage.In addition, it was noted that there were yellow specks on the body of cylinder 1.Both cylinders passed the functional inspection.Based on the information available and analysis results, the reported clinical observation of device bending could not be confirmed; therefore, a conclusion code of cause not established was assigned to this investigation.
 
Event or Problem Description
It was reported that the patient underwent a procedure to remove the ams spectra concealable penile prosthesis because the device was bending.The device was replaced with a tactra malleable penile prothesis.There were no patient complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS SPECTRA CONCEALABLE PENILE PROSTHESIS
Common Device Name
PROSTHESIS PENILE
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
john stoffregen
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key17131443
Report Number2124215-2023-30688
Device Sequence Number6457642
Product Code FAE
UDI-Device Identifier00878953005218
UDI-Public00878953005218
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K090663
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2023
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/22/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/06/2025
Device Model Number720054-02
Device Catalogue Number720054-02
Device Lot Number1000433930
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 05/26/2023
Supplement Date Received by Manufacturer08/07/2023
Initial Report FDA Received Date06/14/2023
Supplement Report FDA Received Date08/22/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/07/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age59 YR
Patient SexMale
-
-