Model Number 3200S
Medical Device Problem Code Loss of or Failure to Bond (1068)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/17/2023
Type of Reportable Event Malfunction
Event or Problem Description
5/19/23 mcarthur complaint #: mca0639 grip-lok not securing tubes.Have had 2 incidents of abdominal tubes falling out and 1 chest tube falling out.The tubes were not in for longer than 2 days.
 
Additional Manufacturer Narrative
The actual complaint product was not available for evaluation.Retain samples from the reported lot were evaluated.Multiple retain samples were tested for adhesive functionality via hanging weight test.All reviewed samples passed the test and functioned per original release specifications.The reported complaint could not be duplicated.The device history record for this lot was reviewed and there were no issues noted that could have contributed to the reported issue.The reporter was contacted for more information regarding the event and the users and it was reported that they are new users who are using the grip-loks as a substitution due to supply chain issues.Previously used devices: statlock and flexitrak.Similar complaints have been reported from former stat-lok users due to the more aggressive adhesive used in that device.The customer has reported that the griplok either fell off the patient completely or the griplok did not move, but the design allowed the tube to slip out entirely from normal patient movement.The adhesive on the top flap did not stick to the tube.Sku 3200s is a small grip-lok intended for use with tubing sizes 4.5 - 14 fr.The customer was contacted for more information on how the device was being used, but no information was received.It is believed that the grip-lok selected was not the correct one for use as described in the incident report, and that a larger model should be used with the tube sizes typically associated with the uses described.The account manager was contacted to provide the customer with alternate skus from the tidi profile to better suit their needs.At this time, it appears that the root cause is related to new users and incorrect device selected for its application.The reporter is being provided with alternate products to better suit their needs.No further corrective or preventive actions are required currently.All complaints are trended and reviewed by management on a monthly basis.As part of this monthly review, any excursion above the control limits for this failure mode will be assessed, documented and acted upon as warranted.Manufacturer reference file (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GRIP-LOK SMALL STERILE
Common Device Name
DEVICE, INTRAVASCULAR CATHETER SECUREMENT
Manufacturer (Section D)
TIDI PRODUCTS LLC
570 enterprise drive
neenah WI 54956
Manufacturer Contact
chris rahn
570 enterprise drive
neenah, WI 54956
9207514300
MDR Report Key17140012
Report Number2182318-2023-00053
Device Sequence Number14435467
Product Code KMK
UDI-Device Identifier00618125134656
UDI-Public00618125134656
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Distributor
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 05/19/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Model Number3200S
Device Catalogue Number3200S
Device Lot Number54958082
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/19/2023
Initial Report FDA Received Date06/15/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-