Model Number 72200146
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/20/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during an acl reconstruction surgery, when tightening the suture loop of the endobutton, the bone tunnel got damage, in the tendon traction, the bone canal cracked and could no longer fixed with tabs.The procedure was completed using a different surgical technique (compression of biosure device fixations) in the originally drilled hole, with a non-significant surgical delay.After the surgery, no damage was found to the patient and no complications were found.No further complications were reported.
 
Additional Manufacturer Narrative
Internal complaint reference (b)(4).
 
Additional Manufacturer Narrative
Internal complaint reference (b)(4).The reported device was received for evaluation.A visual inspection revealed that the device was not in its original packaging.The endobutton was returned without the dtex loop or green suture string.The white suture string was returned.There was debris on the device.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specifications upon release for distribution.A complaint history review found no similar reported events.A risk management review found that the reported failure and/or harm was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate.The root cause could not be determined since the reported malfunction could not be duplicated during the investigation.Please refer to the instructions for use for precautions and warnings related to the use of the device.No containment or corrective actions are recommended at this time.
 
Additional Manufacturer Narrative
Internal complaint reference (b)(4).
 
Event or Problem Description
It was reported that during an acl reconstruction surgery, when tightening the suture loop of the endobutton, the bone tunnel got damage, in the tendon traction, the bone canal cracked and could no longer fixed with tabs.The procedure was completed using a different surgical technique (compression of biosure device fixations) in the originally drilled hole, with a surgical delay greater than 30min.After the surgery, no damage was found to the patient and no complications were found.No further complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDOBUTTON CL ULTRA 15MM
Common Device Name
ACCESSORIES,ARTHROSCOPIC
Manufacturer (Section D)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer (Section G)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key17172900
Report Number1219602-2023-00978
Device Sequence Number12587758
Product Code NBH
UDI-Device Identifier03596010597250
UDI-Public03596010597250
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/27/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/17/2026
Device Model Number72200146
Device Catalogue Number72200146
Device Lot Number2077171
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/01/2023
Supplement Date Received by Manufacturer02/21/2024
02/21/2024
Initial Report FDA Received Date06/21/2023
Supplement Report FDA Received Date02/23/2024
02/27/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/17/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-