Catalog Number 8065751185
Medical Device Problem Code Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/05/2023
Type of Reportable Event Malfunction
Event or Problem Description
A customer reported that the endoilluminator was stuck in trocar during surgery with no patient contact.The surgery was completed after replacing the product with new one.There was no patient harm reported.
 
Additional Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Additional Manufacturer Narrative
The opened illuminator returned for evaluation for the report was not within the final lot number reported based on radio frequency identification tag identification; therefore, no sample evaluation was performed.A review of the device history record traceable to the reported lot number, indicates that the reported product was processed and released according to the reported product¿s acceptance criteria.Since the sample associated with the reported product and lot number was not received at the manufacturing site, and the device history record review of the lot number provided indicated the product was processed and released according to the product¿s acceptable criteria; the root cause for the customer complaint issue cannot be determined.The returned sample was not within the final lot number based on radio frequency identification tag identification; therefore, specific actions with regard to this complaint cannot be taken.All fiber optic light guide products are 100% visually inspected and light tested for transmittance and image during manufacturing.Complaints are reviewed and monitored at regular intervals for any significant adverse trends.No adverse trends have been observed associated with the reported product and event.No further actions are required.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FIBER OPTIC ILLUMINATOR
Common Device Name
LIGHT, SURGICAL, FIBEROPTIC
Manufacturer (Section D)
ALCON RESEARCH, LLC - HOUSTON
9965 buffalo speedway
houston TX 77054
Manufacturer (Section G)
ALCON RESEARCH, LLC - HOUSTON
9965 buffalo speedway
houston TX 77054
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key17191420
Report Number1644019-2023-00760
Device Sequence Number12615879
Product Code FST
UDI-Device Identifier00380657511853
UDI-Public00380657511853
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K875005
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 10/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/30/2024
Device Catalogue Number8065751185
Device Lot Number2503501H
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/29/2023
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date06/23/2023
Supplement Report FDA Received Date10/20/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/21/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-