Manufacturer¿s ref.No: (b)(4).Information regarding patient identifier, date of birth, age, gender, weight, race, and ethnicity were not provided.Section d.4: the expiration date of the device is not known as the device lot number is not available / not reported.Section e.1: the name, phone and email address of the initial reporter are not available / reported.Section h.4: the device manufacture date is not known as the device lot number is not available / not reported.Based on complaint information, the device is not available to be returned for analysis.The device lot number was not available.The manufacturing documentation review could not be performed without the lot number.Product analysis cannot be conducted as the product was not returned for analysis.No determination of causes and possible contributing factors could be made.As such, the investigation will be closed.Intracranial hemorrhage is a known complication associated with the use of the embotrap iii device and is mentioned in the instructions for use (ifu) as such.Clinical and procedural factors, including vessel characteristics, device selection, device interaction (as stated by the treating physician) and operator technique, may have contributed to the adverse event rather than the design or manufacture of the device.Although there was no reported device performance issue/ malfunction- the event meets us fda mdr reporting criteria under 21 cfr 803 with the classification of ¿serious injury.¿ the file will be re-reviewed if additional information is received at a later date.As part of the post market surveillance program, information from this complaint is trended for statistical signals and corrective / preventive action may be triggered at a later time.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
|
The healthcare professional reported that on (b)(6) 2023, a patient with a history of atrial fibrillation underwent a mechanical thrombectomy procedure for an acute ischemic stroke (ais) with the target occlusion in the middle cerebral artery (mca).The physician uses the embotrap frequently on a daily basis, ¿so no problem with its use or technique.¿ the mechanical thrombectomy procedure was targeting an m2 occlusion using a 5mm x 22mm embotrap iii revascularization device (et309522 / lot#: unknown) via a trak microcatheter (stryker).The thrombus was successfully retrieved and recanalization was achieved, but post-operative computed tomography (ct) images showed minor bleeding.The asymptomatic intracranial hemorrhage occurred and no special intervention was required.The patient was asymptomatic and was placed under observation.The patient was then reported to be discharged from the hospital ¿on a later date, after good improvement was observed.¿ continuous flush was maintained during the procedure.The physician commented that ¿there is causal relationship between the issue and the product.The multiple passes at the lesion site might have influenced the issue.Also, endothelial damage by the aspiration catheter could be occurred.¿ the embotrap iii device was used in accordance with the instructions for use (ifu).
|
|
Manufacturer¿s ref.No: (b)(4).The purpose of this mdr submission is to include the additional event information received on 26-jul-2023.[additional information]: on 26-jul-2023, additional information was received.The information indicated anonymized procedure images are not available.The patient suffered an asymptomatic intracranial bleed; details related to the bleed could not be obtained.Endothelial damage by the aspiration catheter could have caused the bleed.The physician think that ¿the multiple passes at the lesion site may have caused the issue.Also, endothelial damage by the aspiration catheter could have occurred.¿ there was no device performance issue related to the embotrap iii device.The reported issue did not result in any clinically significant delay in the procedure.Section e.1: initial reporter phone: (b)(6) the manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
|
Manufacturer¿s ref.No: (b)(4).The purpose of this mdr submission is to include the additional event information received on 05-sep-2023.[additional information]: on 05-sep-2023, additional information was received.The information indicated that the patient is an 86-year old male.The pre- / post- tici scores was tici 3, it was not specified whether this was pre- or post-procedure.The clot was relatively small ¿due to m2 obstruction.¿ the baseline aspects score was 10.Post-procedure nihss score was 0.The patient¿s hospitalization was not prolonged.The embotrap iii made a total of one (1) pass.The aspiration catheter used was a penumbra 4max reperfusion catheter.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|