Model Number 48007004S
Medical Device Problem Code Burst Container or Vessel (1074)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/08/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, the saber pta was used but it ruptured at 6 atm during its initial inflation.The complaint device was replaced with another saber (8mm*4cm) and the procedure completed.There was no reported injury to the patient.This was a vaivt case.The lesion was a stenosis at the brachial veins.A unknown guidewire (0.018) crossed the lesion.The device will not be returned for evaluation.Additional information was requested; however, the information could not be obtained.
 
Additional Manufacturer Narrative
After further review of additional information received the following sections have been updated accordingly: b5, d4, g3, h1, h2, h3 and h6 as reported, the saber pta was used but it ruptured at six atm during its initial inflation.The complaint device was replaced with another saber (8mm*4cm) and the procedure completed.There was no reported injury to the patient.This was a vaivt case.The lesion was stenosis at the brachial veins.An unknown guidewire (0.018) crossed the lesion.Additional information was requested; however, the information could not be obtained.The device was not returned for analysis.A product history record (phr) review of lot 82232907 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿balloon burst-at/below rbp¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.Vessel characteristics of stenosis may have contributed to the reported event, as damage to balloon material may have occurred during crossing or upon inflation.However, without the return of the device for analysis it is difficult to draw a clinical conclusion between the device and the event reported.According to the warnings in the safety information in the instructions for use ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.The balloon dimensions are printed on the product label.The compliance table incorporated with the product shows how balloon diameter increases as pressure increases.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Use only the recommended balloon inflation medium (a 50/50 mixture by volume of contrast medium and normal saline).Never use air or any gaseous medium to inflate the balloon.¿ neither the phr nor the information available suggests a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
 
Event or Problem Description
As reported, the saber pta was used but it ruptured at 6 atm during its initial inflation.The complaint device was replaced with another saber (8mm*4cm) and the procedure completed.There was no reported injury to the patient.This was a vaivt case.The lesion was a stenosis at the brachial veins.A unknown guidewire (0.018) crossed the lesion.The device will not be returned for evaluation.Additional information was requested; however, the information could not be obtained.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SABER
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
CORDIS US. CORP
14201 nw 60 avenue
miami lakes, florida 33014
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
coyol free zone, building b25, ,  , costa rica
el coyol alajuela bld 25 
7863138372
MDR Report Key17238854
Report Number3007635982-2023-00227
Device Sequence Number7091194
Product Code LIT
UDI-Device Identifier20705032068847
UDI-Public(01)20705032068847(17)240831(10)82232907
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K971010
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 07/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date08/31/2024
Device Model Number48007004S
Device Catalogue Number48007004S
Device Lot Number82232907
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer07/05/2023
Initial Report FDA Received Date06/30/2023
Supplement Report FDA Received Date07/12/2023
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured09/14/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
PIOLAX 0.018 WIRE; SABER (8MM*4CM); UNKNOWN GUIDEWIRE (0.018)
Patient SexUnknown
-
-