Catalog Number 20059E
Medical Device Problem Code Defective Component (2292)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/20/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during ct infustion with bd smartsite¿ extension set, 1 smartsite¿ needle-free connector the tubing was defective.This is the 1st of 2 events.The following information was provided by the initial reporter: my clinicians had two of our j loops (smartsite¿ extension set) pop during a ct infusion.They used 3.5 pressure.They determined the iv catheter worked on hub, so that wasn't the issue.
 
Additional Manufacturer Narrative
Date of event: unknown.The date received by manufacturer has been used for this field.Medical device expiration date: unknown.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device manufacture date: unknown.
 
Event or Problem Description
It was reported that during ct infustion with bd smartsite¿ extension set, 1 smartsite¿ needle-free connector the tubing was defective.This is the 1st of 2 events.The following information was provided by the initial reporter: my clinicians had two of our j loops (smartsite¿ extension set) pop during a ct infusion.They used 3.5 pressure.They determined the iv catheter worked on hub, so that wasn't the issue.
 
Additional Manufacturer Narrative
The following fields have been updated due to additional information: d.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 21-jul-2023.H.6.Investigation summary: one sample was received for quality investigation.The customer complaint of tubing defective was confirmed by investigation.Evaluation of the extension set submitted show that the tubing was burst just before the male luer adapter connection.A device history record review for model 20059e lot number 22099016 was performed.The search showed that a total of (b)(4) units in 1 lot number was built on 01sep2022.There were no quality notifications issued for the failure mode reported by the customer during the production build of this set.The root cause for the failure could not be determined.The manufacturing location has been made aware of the failure and an investigation could not indicate an issue with the tubing that may have caused it to burst in the manner seen in the sample.The clinical team has been contacted with the customer regarding the issue, in order to determine if further training or guidance is needed for the proper use of the extension sets.This incident has been added to our database of reported incidents.Our business team regularly reviews the collected data for identification of emerging trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD SMARTSITE¿ EXTENSION SET, 1 SMARTSITE¿ NEEDLE-FREE CONNECTOR
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8448235433
MDR Report Key17299312
Report Number9616066-2023-01402
Device Sequence Number12521711
Product Code FPA
UDI-Device Identifier07613203012317
UDI-Public07613203012317
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K960280
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number20059E
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/20/2023
Supplement Date Received by Manufacturer10/20/2023
Initial Report FDA Received Date07/11/2023
Supplement Report FDA Received Date10/24/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-