Model Number IPN915197
Medical Device Problem Code Loose or Intermittent Connection (1371)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/21/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Qn#(b)(4).Other remarks: n/a.Corrected data: n/a.
 
Event or Problem Description
It was reported that the screw of the handle was found loose when checking it at the hospital supply room.No patient involvement.
 
Additional Manufacturer Narrative
Qn# (b)(4).The sample was returned and sent to the manufacturing site (tecomet) for investigation.Tecomet reports "the dhr for the returned instrument was reviewed and found complete without any irregularities.This instrument was produced at the tecomet, inc.Kenosha wi facility as part of a 50-pc.Lot in september of 2021.It was found that this order was made from the correct materials and components and all approved processes were followed.Evaluation of the returned instrument as received shows that the endo handle pivot screw (n00186) is easily backed out of its threading which signifies that the staking operation that holds the screw in place in between the g00436m handle has failed.Further evaluation shows that the staking operation has been performed at the time of manufacture.We are unable to determine what cause the screw to become loose from its staking operation since we do not know how this instrument has been handled out in the field since its date of production.Mishandling of this device at the end user's facility is suspected.All 50 instruments from this lot were 100% visually inspected and function tested prior to shipment to the customer as this is a standardized procedure at this facility for this product line.Due to these findings, no further actions will be taken in response to this complaint and this record will be deemed closed.".
 
Event or Problem Description
It was reported that the screw of the handle was found loose when checking it at the hospital supply room.No patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HOL L 10MM ENDO APPLIER
Common Device Name
APPLIER, SURGICAL, CLIP
Manufacturer (Section D)
TELEFLEX MEDICAL
morrisville NC
Manufacturer (Section G)
TELEFLEX MEDICAL
3015 carrington mill blvd
morrisville NC 27560
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key17321358
Report Number3011137372-2023-00186
Device Sequence Number17877747
Product Code GDO
UDI-Device Identifier24026704696837
UDI-Public24026704696837
Combination Product (Y/N)N
Initial Reporter CountryJA
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIPN915197
Device Catalogue Number544995
Device Lot Number06K2005185
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/21/2023
Supplement Date Received by Manufacturer09/28/2023
Initial Report FDA Received Date07/13/2023
Supplement Report FDA Received Date09/29/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.; N/A.
Patient SexUnknown
-
-