• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON & CO. (SPARKS) BD BBL¿ TRYPTICASE¿ SOY BROTH; CULTURE MEDIA, NON-SELECTIVE AND NON-DIFFERENTIAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON & CO. (SPARKS) BD BBL¿ TRYPTICASE¿ SOY BROTH; CULTURE MEDIA, NON-SELECTIVE AND NON-DIFFERENTIAL Back to Search Results
Model Number 221823
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/10/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that while using bd bbl¿ trypticase¿ soy broth, there was contamination of an unspecified number of plates.No patient impact reported.The following information was provided by the initial reporter: "customer reports that they have previous received lots that had contaminated tubes.".
 
Additional Manufacturer Narrative
Medical device expiration date: unknown a device evaluation and/or device history review is anticipated but is not complete.Upon completion, a supplemental report will be filed.Device manufacture date: unknown.
 
Additional Manufacturer Narrative
H.6.Investigation summary: material 221823 is manufactured by rehydrating the media components with usp purified water, and thoroughly mixing until a homogeneous solution is obtained.The tubes are terminally autoclaved in an air over pressure (aop) autoclave, per manufacturing instructions, using a validated cycle.Post autoclaving, tubes are packaged into final shipping configurations.The customer did not provide a batch number, photos or returns for this complaint investigation.Trending was done on the appropriate databases for trypticase soy broth (tsb 15ml) (material 221823) and no quality notification trends have been identified for this material for broken/cracked tubes or contamination in the last 12 months.The complaint history was reviewed for material 221823 and there are no trends for broken or cracked tubes or contamination in the last 12 months.Bd will continue to trend complaints for these issues.This complaint cannot be confirmed based on material trending.No additional actions are indicated at this time.
 
Event or Problem Description
It was reported that while using bd bbl¿ trypticase¿ soy broth, there was contamination of an unspecified number of plates.No patient impact reported.The following information was provided by the initial reporter: "customer reports that they have previous received lots that had contaminated tubes.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD BBL¿ TRYPTICASE¿ SOY BROTH
Common Device Name
CULTURE MEDIA, NON-SELECTIVE AND NON-DIFFERENTIAL
Manufacturer (Section D)
BECTON DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer (Section G)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer Contact
jennifer suh
5859 farinon drive
san antonio, TX 78249
8448235433
MDR Report Key17344398
Report Number1119779-2023-00783
Device Sequence Number20464139
Product Code JSG
UDI-Device Identifier30382902218235
UDI-Public30382902218235
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
PREAMENDMENT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/07/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model Number221823
Device Catalogue Number221823
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/10/2023
Supplement Date Received by Manufacturer09/07/2023
Initial Report FDA Received Date07/18/2023
Supplement Report FDA Received Date09/12/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-