| Model Number |
TB-TSCRW-01M |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Loss of Range of Motion (2032); Scar Tissue (2060); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
06/23/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The investigation is in process.The device will not be returned for evaluation.When the investigation is complete, a supplemental mdr will be submitted accordingly.Multiple mdrs were submitted for this event: #3013450937-2023-00131, #3013450937-2023-00132, #3013450937-2023-00133, #3013450937-2023-00134, #3013450937-2023-00135, #3013450937-2023-00136, #3013450937-2023-00137, #3013450937-2023-00138, #3013450937-2023-00139, #3013450937-2023-00141.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient underwent a revision surgery due to patella baja and flexion contracture.During the revision surgery, the surgeon identified that the patient had developed bone osteophytes and scar tissue formation.The surgeon removed as much scar tissue and bone osteophytes as possible.The surgeon revised the distal femur, distal femur axial pin, tibial poly spacer, tibial hinge component, and male-female midsection.The following implants remain implanted from the patient's original surgery: biogrip ha collar, collar locking ring, segmental stem, tibial baseplate, tibial baseplate tapered screw, and stem extension.No additional information regarding this adverse event has been reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted to include additional information.The investigation is complete.The device was not returned for evaluation.The device history records and sterilization batch records were reviewed and there were no non-conformances identified that would have contributed to this complaint.If additional information is obtained, a supplemental mdr will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient underwent a revision surgery due to patella baja and flexion contracture.During the revision surgery, the surgeon identified that the patient had developed bone osteophytes and scar tissue formation.The surgeon removed as much scar tissue and bone osteophytes as possible.The surgeon revised the distal femur, distal femur axial pin, tibial poly spacer, tibial hinge component, and male-female midsection.The following implants remain implanted from the patient's original surgery: biogrip ha collar, collar locking ring, segmental stem, tibial baseplate, tibial baseplate tapered screw, and stem extension.No additional information regarding this adverse event has been reported.
|
| |
|
Search Alerts/Recalls
|
|