| Catalog Number |
VCP839D |
| Medical Device Problem Code |
Material Integrity Problem (2978)
|
| Health Effect - Clinical Codes |
Wound Dehiscence (1154); Bacterial Infection (1735); Pocket Erosion (2013); Discomfort (2330); Impaired Healing (2378); Fluid Discharge (2686)
|
| Date of Event |
01/01/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a patient underwent a lumbar 4-lumbar 5 posterior spinal instrumented fusion and decompression procedure on (b)(6) 2023 and suture was used.Post op the sutures were not dissolving and were being rejected.Additional information was requested.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint #: (b)(4).H6.Component code: g07002 - device not returned.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested, and the following was obtained: was there any adverse consequence associated with the patient? (b)(6) 2023 patient with scant "bloody drainage" on her shirt at her follow-up appointment.On (b)(6) 2023 she endorsed moderate incision discomfort near surgical site and there was delayed surgical wound healing as the superficial layer of the wound bed has not yet adhered with notable scabbing/eschar in the wound bed.The patient was referred to wound care and seen them on (b)(6) 2023 and wound debridement was performed at the sq.Level and serous drainage.X2 small sutures removed that was not absorbed.The patient was started on doxycycline.(b)(6) 2023 follow-up with wound care and debridement again at the sq.Level.(b)(6) 2023 to ed with drainage "straw colored".(b)(6) 2023 back to or for irrigation and debridement abscess deep posterior spine.Positive cultures from deep wound of pseudomonas aeruginosa.Patient referred to infectious disease.What is the current status of the patient? following with infectious disease due to pseudomonas aeruginosa.Was there any medical or surgical intervention performed (product removed; re-operation; re-suturing; re-closure; drainage)? if so, please specify.(b)(6) 2023 wound debridement x2 small sutures removed that was not absorbed 2-0 vicryl sutures.Dehiscence present.Doxycycline rx.(b)(6) 2023 surgery: irrigation and debridement abscess deep posterior spine, serosanguious drainage.Re-closure of muscle and fascia with 0 vicryl suture, fat 0 vicryl sutures, subcutaneous tissue closed with 2-0 vicryl sutures, skin with 3-0 nylon suture.If product was removed: what was the appearance of the suture during the removal? no description documented description of sutures removed on (b)(6) 2023.If re-suture/re-closure was performed: was reoperation necessary to remove the suture and re-close the wound? yes for re-close the wound (b)(6) 2023.Was the suture trimmed in physician¿s office? no.Was the suture removed in a routine post-op procedure? no.Was the suture removed in a reoperation procedure? no, they were removed in debridement in wound care.Could you tell me if there was a prescription for steroids or antibiotics for the patient's recovery? if yes, please provide medication name, route and dose.(b)(6) 2023 doxycyline monohydrate 100mg tablet: 1 tablet po q12hr for 10 days.(b)(6) 2023 vancomycin (b)(6) 2023 1250mg iv.(b)(6) 2023 ciprofloxacin 500mg: 1 tablet po bid for 14 days (stopped (b)(6) 2023).(b)(6) 2023 levofloxacin 750mg 1 tablet po daily for 7 days.Cefepime 2g q8hr for 6 weeks iv.What was the name of the procedure? lumbar 4-lumbar 5 posterior spinal instrumented fusion and decompression.What was the procedure date? (b)(6) 2023.Please provide the lot number: unknown lot number.Supply number: sxpp1a205-suture stratafix, vcp839d-suture vicryl plus 2-0 & vcp840d-suture vicryl 0 ct-1.Event related to mw # 2210968-2023-05532, mw # 2210968-2023-05534.This is a combination product, and the event has been reviewed for both the suture and the triclosan.Trade name - irgacare®.Active ingredient(s) ¿ triclosan.Dosage form ¿ suture/solid/parenteral.Strength ¿ = 472 g/m.This report is being submitted pursuant to the provisions of 21 cfr part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information was requested, and the following was obtained: age, gender, weight, bmi at the time of index procedure 46f, 91.491kg, 34.69 what was the tissue condition (normal, thin, calcified, fragile, diseased) normal for vicryl suture- how was the suture placed (interrupted or continuous)? interrupted for vicryl suture - how was the suture originally tied (multiple knots, square knot, etc.)? unknown for stratafix symmetric pds plus - was the fixation tab seated against the tissue at the initiation of suture use during the index procedure? unknown documented as "running 1-0 stratafix suture).For stratafix symmetric pds plus - were two reverse stitches performed across the incision prior to closure? unknown documented as "running 1-0 stratafix suture).What tissue layer(s) dehisced? subcutaneous did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation? no documentation or report of issues other relevant patient history/concomitant medications? n/a what is the physician¿s opinion as to the etiology of or contributing factors to this event? no documentation.Only comment of "x2 small sutures removed that was not absorbed" by wound care provider.Corrected information: h6 type of investigation.
|
| |
|