Model Number 15-3816/11
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Joint Laxity (4526)
Date of Event 01/06/2023
Type of Reportable Event Serious Injury
Event or Problem Description
This tinbn-coated hinged knee was implanted (b)(6) 2022 (femoral components and tibial plateau) and (b)(6) 2022 (tibial tray and stem) as a temporary spacer for the 1st stage in a planned 2 stage revision for infection (with definitive prosthesis to be custom-made by another supplier).This tinbn-coated hinged knee was used as a temporary spacer because of the patient's nickel allergy.The patient presented to the er and underwent revision surgery (b)(6) 2023 due to dissociation of the femoral component from femoral stem.The femoral stem, femoral augment, femoral component, and tibial plateau were replaced, with the construct still being intended as a temporary spacer, anticipating later conversion to definitive custom-made implants.Prior surgeries on this knee include: primary and revision tka (not link product), revision with link compassionate use components (b)(6) 2022 ((b)(4)), and subsequent revisions (b)(6) 2022 and (b)(6) 2022 for infection (previously reported in complaint (b)(4)) and for dissociation of femoral component from stem (same stem as previous event in complaint (b)(4)).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDO-MODEL MODULAR KNEE PROSTHESIS SYSTEM
Common Device Name
ENDO-MODEL MODULAR KNEE PROSTHESIS SYSTEM
Manufacturer (Section D)
WALDEMAR LINK GMBH & CO. KG
barkhausenweg 10
hamburg, 22339
GM  22339
MDR Report Key17445501
Report Number3006721341-2023-00020
Device Sequence Number2494450
Product Code KRO
UDI-Device Identifier04026575034741
UDI-Public(01)04026575034741(17)270131
Combination Product (Y/N)N
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Device Explanted Year2023
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 08/02/2023
Report Date (Section F) 07/26/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Model Number15-3816/11
Device Catalogue Number15-3816/11
Device Lot Number200818
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Distributor Facility Aware Date07/25/2023
Event Location Hospital
Date Report to Manufacturer07/26/2023
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date08/02/2023
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age76 YR
Patient SexFemale
Patient Weight109 KG
-
-