COOK IRELAND LTD EVOLUTION® ESOPHAGEAL CONTROLLED-RELEASE STENT - PARTIALLY COVERED; ESW PROSTHESIS, ESOPHAGEAL Back to Search Results
Catalog Number EVO-20-25-8-E
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Obstruction/Occlusion (2422)
Date of Event 05/04/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Pma/510(k) #k162717.Investigation is still pending, a follow up mdr will be submitted to include the investigation conclusions.
 
Event or Problem Description
Stent obstruction and safety wire breakage resulting in pain and nausea + user error: stent repositioning.On (b)(6) 2022, a stent was placed in the patient's esophagus due to dysphagia.On (b)(6) , a month later, it turned out that the mucosa of the esophagus was overgrown with a stent from both ends.And the safety wire is broken.It became impossible to remove a stent.Pet-ct showed that the lumen of the stent was obstructed, so on (b)(6), the stent was lifted a little higher by gastroscopy.The patient had persistent severe pain and nausea as a result of stent placement.User error: patient treated with chemotherapy (as per ifu: after stent placement alternative methods of treatment such as chemotherapy should not be administered).On (b)(6) 2022, the patient began a weekly course of chemotherapy with paclitaxel and carboplatin.In about 10 days after the start of chemotherapy, the pressure/pain and nausea went away, but for the last 10 days the patient started to feel pain and difficulty at swallowing, so a chest ct was done, which showed that the oncological nodules had shrunk and pressure on the esophagus has been lifted, although it turned out that the mucosa of the esophagus was overgrown with a stent from both ends.User error: attempted removal of device (as per ifu: this stent is not intended to be removed and is intended to remain in the body permanently).A plan was developed to remove the stent by gastroscopy, but it turned out that the mucosa of the esophagus was overgrown with a stent from both ends.The threads at the ends of the stent were torn.It became impossible to remove the stent (they tried to remove the stent twice but neither tries were successful).As there is no solution to this issue, the oncologist temporarily suspended chemotherapy, because we do not know what type of intervention will be necessary, and due to the recent interventions, the patient had fever, irritation of respiratory tract, nausea, difficulty swallowing and pain in the stent/esophagus area.The patient is in a hard physical and emotional condition.Due to the complication with stent vitally important for her chemotherapy was stopped.Stent removal is the most important on this stage.This file will capture the stent obstruction observed.It is impossible to remove the stent, that esophageal mucosa is stuck in uncovered sites of the stent.The threads at the ends of the stent are torn.The patient is in a hard physical and emotional condition.Due to the complication with stent vitally important for him chemotherapy was stopped.Please share your experience how this problem can be solved, what ways you recommend to remove the stent.A plan was developed to remove the stent by gastroscopy, but it turned out that the mucosa of the esophagus was overgrown with a stent from both ends.The threads at the ends of the stent were torn.It became impossible to remove the stent (they tried to remove the stent twice but neither tries were successful).As there is no solution to this issue, the oncologist temporarily suspended chemotherapy, because we do not know what type of intervention will be necessary, and due to the recent interventions, the patient had fever, irritation of respiratory tract, nausea, difficulty swallowing and pain in the stent/esophagus area.The patient is in a hard physical and emotional condition.Due to the complication with stent vitally important for her chemotherapy was stopped.Stent removal is the most important on this stage.
 
Event or Problem Description
Supplemental report is being submitted due to the completion of the investigation on 30-nov-2023.
 
Additional Manufacturer Narrative
Pma/510(k) #k162717.Device evaluation: the device evaluation evo-20-25-8-eof lot c1906670 could not be completed as the device or photographic evidence of the device was not returned for evaluation.This file is related to pr 368137, emdr 3001845648-2022-00484 (stent obstruction and safety wire breakage resulting in pain and nausea), pr 369524, emdr 3001845648-2022-00485(user error: patient treated with chemotherapy) and pr 369526, emdr 3001845648-2022-00486 (user error: attempted removal of device).Manufacturing records: prior to distribution all devices are subjected to a visual inspection and functional inspection to ensure device integrity.A review of the manufacturing records of lot number c1906670 did not reveal any discrepancies that could have contributed to this complaint issue.Review historical data: the review of relevant manufacturing records of lot number c1906670 confirms the failure mode has not previously occurred for this work order.Instructions for use and/label : the instructions for use, ifu0061 which accompanies this device, instructs the user: ¿¿ additional complications include, but are not limited to: stent misplacement and/or migration; tumour ingrowth or overgrowth; oesophageal ulceration and erosion; nausea; chest or retrosternal pain; foreign body sensation; food bolus.¿¿ there is no evidence to suggest that the customer did not follow the instructions for use.Image review: an image was not returned for evaluation.Root cause analysis: definitive root cause could not be established.A possible root cause could be attributed to patient condition related, as per instructions for use, tumour ingrowth or overgrowth is listed as a complication following the use of this device.Confirmation of complaint: complaint is confirmed based on customer and/or rep testimony.Corrective action/ correction: complaints of this nature will continue to be monitored for potential emerging trends.Summary of investigation: according to the customer the stent was obstructed which led them to repositioning the stent.Confirmed quantity of 1 device, confirmed used.The patient did not experience any adverse effects due to this occurrence.The patient is in a hard physical and emotional condition after the repositioning , chemotherapy and attempted removal of the stent.Investigation findings conclude that a possible root cause could be attributed to patient condition related.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVOLUTION® ESOPHAGEAL CONTROLLED-RELEASE STENT - PARTIALLY COVERED
Common Device Name
ESW PROSTHESIS, ESOPHAGEAL
Manufacturer (Section D)
COOK IRELAND LTD
o halloran road
limerick
Manufacturer (Section G)
COOK IRELAND LTD
o halloran road
national technology park
limerick
Manufacturer Contact
sinead o'leary
o halloran road
national technology park
limerick 
MDR Report Key17486562
Report Number3001845648-2023-00605
Device Sequence Number20646307
Product Code ESW
UDI-Device Identifier10827002480305
UDI-Public(01)10827002480305(17)240124(10)C1906670
Combination Product (Y/N)N
Initial Reporter CountryGG
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/24/2024
Device Catalogue NumberEVO-20-25-8-E
Device Lot NumberC1906670
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Distributor Facility Aware Date05/04/2022
Event Location Hospital
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/12/2023
Supplement Date Received by Manufacturer07/12/2023
Initial Report FDA Received Date08/09/2023
Supplement Report FDA Received Date12/18/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/24/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age37 YR
Patient SexFemale
-
-