| Catalog Number |
1859660 |
| Medical Device Problem Codes |
Loss of or Failure to Bond (1068); Fracture (1260); Difficult to Insert (1316); Material Separation (1562)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
05/18/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during a port placement procedure, one half of the plastic ring of the sheath allegedly broke off.It was reported that it was allegedly difficult to insert into the sheath and vein.Reportedly, the catheter was able to get into the vein and the procedure was completed.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
As the lot number for the device was provided, a review of the device history records is currently being performed.The return of the sample is pending.The investigation of the reported event is currently underway.D4 (expiry date: 07/2024).The information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that during a port placement procedure, one half of the plastic ring of the sheath allegedly broke off of the sheath.It was further reported that it was allegedly difficult to insert the catheter into the sheath and vein.Reportedly, the catheter was able to be get into the vein and the procedure was completed.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one fully peeled 10.0fr peel-apart sheath was returned for evaluation.Gross visual, microscopic and functional evaluations were performed.One valve cap was received detached from the t-handle.The other half of the valve cap was fully attached to the t-handle.Therefore, the investigation has been confirmed for identified material separation and loss of bond issues.The investigation is unconfirmed for fracture issue as the more appropriate failure material separation has been confirmed.Also, the investigation remains inconclusive for the reported difficult to insert as the exact circumstances could not be reproduced and the catheter was not returned.The definitive root cause was determined to be manufacturing related issue.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H10: b5, d4 (expiry date: 07/2024), g3, h6 (device).H11: h6 (method, result, conclusion).H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
|
| |
|
Additional Manufacturer Narrative
|
|
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one fully peeled 10.0fr peel-apart sheath was returned for evaluation.Gross visual, microscopic and functional evaluations were performed.One valve cap was received detached from the t-handle.The other half of the valve cap was fully attached to the t-handle.Therefore, the investigation has been confirmed for identified material separation and loss of bond issues.The investigation is unconfirmed for fracture issue as the more appropriate failure material separation has been confirmed.Also, the investigation remains inconclusive for the reported difficult to insert as the exact circumstances could not be reproduced and the catheter was not returned.The definitive root cause could not be determined based upon available information.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that during a port placement procedure, one half of the plastic ring of the sheath allegedly broke off of the sheath.It was further reported that it was allegedly difficult to insert the catheter into the sheath and vein.Reportedly, the catheter was able to be get into the vein and the procedure was completed.There was no reported patient injury.
|
| |
|