| Catalog Number |
208-22-09 |
| Medical Device Problem Codes |
Structural Problem (2506); Device Dislodged or Dislocated (2923); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Osteolysis (2377)
|
| Date of Event |
11/30/2009
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
D2b: prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer.Pending investigation.These devices are used for treatment not diagnosis.There is no other information available.
|
| |
|
Event or Problem Description
|
|
As reported via legal documentation a patient had an initial right total knee arthroplasty on (b)(6) 2009 and then approximately 8 months later had a screw used to secure the polyethylene spacer back out "[the spine stiffening screw, backed out of the insert]" it was removed and a new insert and screw were placed.There is no other patient demographic or medical history available.There is no information on the surgical procedure or patient outcome.There is no device return.There are no photos or other images of the device provided.No additional information is available.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: h6.Mdr section codes updated/corrected: a, b, c, d, e, g.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear and femoral loosening or due to inclusion of the polyethylene in the packaging recall.Potential contributions of manufacturing, user, and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images, radiographs, and product information were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: e1, e2, e3, g2, h6, h11.The reported event was unable to be confirmed due to limited information received from the customer.No device was returned for evaluation; further, photographs and/or radiograph images were not provided for review.A review of complaint history determined that no further action is required as no trends were identified.The reason for the revision reported cannot be conclusively determined.The revision may have been reported at this later time due to inclusion of one of the patient¿s implanted devices in the polyethylene packaging recall.Based on the length of implantation, the reason for revision appears unlikely to be secondary to prosthesis wear and is likely the result of loosening of the spine stiffener screw, as reported in the operative notes.However, this cannot be confirmed as the devices were not returned for evaluation and no images or radiographs were provided.
|
| |
|