| Lot Number |
VMFC290523 |
| Medical Device Problem Codes |
Difficult to Remove (1528); Defective Device (2588); Component or Accessory Incompatibility (2897)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/26/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that during a watchman procedure to treat left atrial appendage closure (laac), a versacross connect kit was selected for use.Prior to transseptal puncture, the mechanical j-wire was in superior vena cava (svc) and it frayed/ split when it was pulled into versacross connect sheath.There was resistance felt when withdrawing the wire from the introducer.Both the versacross connect and double curve sheath were removed from the body.Hence to resolve the issue, a new kit was opened and the procedure was completed successfully.No patient complications reported.The device is expected to be returned for analysis.
|
| |
|
Event or Problem Description
|
|
It was reported that during a watchman procedure to treat left atrial appendage closure (laac), a versacross connect kit was selected for use.Prior to transseptal puncture, the mechanical j-wire was in superior vena cava (svc) and it frayed/ split when it was pulled into versacross connect sheath.There was resistance felt when withdrawing the wire from the introducer.Both the versacross connect and double curve sheath were removed from the body.Hence to resolve the issue, a new kit was opened and the procedure was completed successfully.No patient complications reported.The device is expected to be returned for analysis.
|
| |
|
Additional Manufacturer Narrative
|
|
The device has not been received for analysis yet.However, based on the media provided, the reported allegations are confirmed.The photos clearly demonstrate the frayed mechanical guidewire.Also, the fields b7 (other relevant history) and e4 (init rptr also sent rep to fda) were updated.Thus, this supplemental is being filed.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.This product is part of the 97072033-fa epflex guidewire obstruction advisory commencement advisory for the j-tipped mechanical guidewire.
|
| |
|