|
Due to the nature of this reportable event, the customer provided the cleaning sterilization and disinfection (cds) processes performed at the user facility.The customer indicated that cleaning brush 000639 made by japan medical next was used to clean the endoscope in question.The customer did not provide any other steps taken during the cleaning sterilization and disinfection (cds) process.At this time, it has been indicated to olympus that the device will not be returned for testing and evaluation.Should additional information become available, or the evaluation is completed, a follow-up report will be submitted.Related complaints: (b)(6), cf-h290i evis lucera elite colonovideoscope, serial number (b)(6).(b)(6), hx-610-090s short clip, lot number unknown.(b)(6), hx-610-090s short clip, lot number unknown.
|
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.Correction to h8.The device history record (dhr) was unable to be reviewed for this device since the lot number was not provided.However, olympus reviewed dhrs for lot numbers which were manufactured one year before the event date and there were no deviations that could have caused or contributed to the reported issue.Since the subject device could not be confirmed, and no abnormalities were detected in the dhr, the exact cause could not be determined.Based on the results of the investigation, the event was likely caused by the following factors: ·when inserted into the scope's forceps channel, the clip fell out because it protruded inside the scope.·when inserted into the scope's forceps channel, a clipping movement occurred within the scope, causing the clip to break and fall off.The event can be prevented by following the instructions for use which state: ·"once the clip is placed inside the coil sheath, do not poke it out of the coil sheath until you are ready to use it.If it sticks out, it cannot be inserted into the endoscope.·when inserting the rotating clip device into the endoscope, hold the slider firmly.If the slider is not held, the rotating clip device may suddenly protrude from the tip of the endoscope, leading to perforation, major bleeding, mucosal damage, or damage to the endoscope or rotating clip device.·do not make sudden protrusions.It may lead to perforation, heavy bleeding, mucous membrane damage, etc., and may lead to damage to the endoscope or rotating clip device.·do not insert the rotating clip device into the endoscope unless the clip is completely retracted into the coil sheath.It may lead to perforation, heavy bleeding, mucous membrane damage, etc., and may lead to damage to the endoscope or rotating clip device.·do not pull the slider suddenly.The clip opens all at once and then closes." olympus will continue to monitor field performance for this device.
|