| Model Number |
D021 |
| Medical Device Problem Code |
Premature Discharge of Battery (1057)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/06/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
It was reported that this implantable cardioverter defibrillator (icd) recorded an fc 1003 indicative of battery voltage too low for the projected remaining capacity.Additional information received which indicated that this device was submitted for engineering analysis which resulted that this device exhibited a low voltage.There were no other suspicious faults or resets stored within device memory.The battery voltage at the time of interrogation was 3.024 volts, therapy delivery was unaffected.This device remains in service.No adverse patient effects were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.This product has not been returned for analysis.This report will be updated should additional information become available or if analysis is completed.
|
| |
|
Event or Problem Description
|
|
It was reported that this implantable cardioverter defibrillator (icd) recorded an fc 1003 indicative of battery voltage too low for the projected remaining capacity.Additional information received which indicated that this device was submitted for engineering analysis which resulted that this device exhibited a low voltage.There were no other suspicious faults or resets stored within device memory.The battery voltage at the time of interrogation was 3.024 volts, therapy delivery was unaffected.This device remains in service.No adverse patient effects were reported.Additional information received which indicated that this device was explanted and replaced.No additional adverse patient effects were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.This product has not been returned for analysis.This report will be updated should additional information become available or if analysis is completed.The returned device was thoroughly inspected and analyzed.Review of device memory confirmed that a low voltage alert (code 1003) was recorded.A high current drain was detected, but the battery still supported full device function.Detailed analysis confirmed the identified high current drain was a result of compromised low voltage capacitors.Low voltage capacitors are used in the device's high voltage charging operation in order to facilitate fast charge times.Investigation has determined that the low voltage capacitors can become compromised due to the presence of excess hydrogen gas within the device case.The issue with these capacitors resulted in a high current drain, which was depleting this device's battery faster than normal.
|
| |
|
Event or Problem Description
|
|
It was reported that this implantable cardioverter defibrillator (icd) recorded an fc 1003 indicative of battery voltage too low for the projected remaining capacity.Additional information received which indicated that this device was submitted for engineering analysis which resulted that this device exhibited a low voltage.There were no other suspicious faults or resets stored within device memory.The battery voltage at the time of interrogation was 3.024 volts, therapy delivery was unaffected.This device remains in service.No adverse patient effects were reported.Additional information received which indicated that this device was explanted and replaced.No additional adverse patient effects were reported.
|
| |
|