MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 INTERMITTENT ROCHESTER CATHETERS; UNKNOWN INTERMITTENT CATHETERS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 INTERMITTENT ROCHESTER CATHETERS; UNKNOWN INTERMITTENT CATHETERS Back to Search Results
Medical Device Problem Codes Fracture (1260); Scratched Material (3020)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/31/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that customer got 3 boxes of 12 intermittent catheters that were defective, all from the same lot.Customer stated that the end of them was curled over and were very hard.Customer also mentioned that up at the top they were shorter in the packaging, 2 inch shorter than usual.Up at the top of the catheter, the outlet part there were a large bump on it.So, insertion would be difficult because of the hard curl end.Customer request replacement for the defective product.Per follow up via pone (b)(6) 2023, customer stated that they did not use the catheters, they saw the defect before use and wanted to inform the company of the affected lots.Per notification from investigator on (b)(6) 2023, during sample evaluation it was found that the scratch found on the shaft close to the funnel of intermittent catheter.
 
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported that customer got 3 boxes of 12 intermittent catheters that were defective all the same lot.Customer stated that the end of them was curl over and were very hard.Customer also mentioned that up at the top they were shorter in the packaging, 2 inch shorter than usual.Up at the top of the catheter, the outlet part there were a large bump on it.So, insertion would be difficult because of the hard curl end.Customer request replacement for the defective product.Per follow up via pone 08jun2023, customer stated that they did not use the catheters, they saw the defect before use and wanted to inform the company of the affected lots.Per notification from investigator on 31jul2023, during sample evaluation it was found that the scratch found on the shaft close to the funnel of intermittent catheter.
 
Additional Manufacturer Narrative
The reported event was confirmed cause unknown.1 sample were confirmed to exhibit the reported failure.The device had not met specifications.The product was not used for patient treatment.The product caused the reported failure.Gross visual evaluation: no non-conformities were noted with the hardness at the tip of the catheter.Coude curve aligned with the coude indicator notch, some degradation due to oxidation was noted within the eyelets of catheters 1, 2, 3, 4, 5 (very slight signs of oxidation within the eyelets), 6, 8, 9, as this was not reported by the customer, and it is unknown how the catheter was being stored or when the oxidation occurred a new complaint will not be created.Some scratch marks were noted on the funnel of catheters 4, 6 & 9, and a small scratch was noted on the shaft close to the funnel of catheter 10; no scratches or abnormalities were noted on the packaging.This does not meet specification which states that "materials shall be cosmetically clean, outer, and inner surfaces shall be free of dirt, foreign marks, and foreign material when viewed with the unaided eye from a distance of 6¿.Dimensional evaluation: using a french gauge, all catheters were confirmed to be 16fr.The overall length of the catheters was measured and found to be within specification: catheter 1- 15.75", catheter 2 - 15.75", catheter 3 - 15.72", catheter 4 - 15.75", catheter 5 - 15.81", catheter 6 - 15.87", catheter 7 - 15.75", catheter 8 - 16.00", catheter 9 - 16.00", catheter 10 - 15.87".A potential root cause for this failure mode could be ¿rough insertion-sleeve surface scratches hydrophilic coating or removes coating".The device history record review could not be performed without a lot number.The instructions for use were found adequate and state the following: ¿caution: this product contains natural rubber latex which may cause allergic reactions.Warnings: on latex and red rubber catheters, do not use ointments or lubricants having a petrolatum base.They will damage latex.Visually inspect the product for any imperfections or surface deterioration prior to use.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to failure, and/or to injury, illness or death of the patient.Note: after use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Adverse reactions: urinary tract infection.Bleeding from the urethra.Irritation of the urethra.Instructions for intermittent catheters: 1.Wash your hands thoroughly with soap and water.2.Remove catheter from the pack.3.Position yourself comfortably, cleaning the opening of the urethra and surrounding area.4.Gently insert rounded end of catheter into urethra.5.When urine stops flowing, remove catheter from urethra.6.Dispose of catheter in accordance with local rules and regulations.7.Wash your hands.¿ h11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the actual/suspected device was inspected.
 
Event or Problem Description
It was reported that customer got 3 boxes of 12 intermittent catheters that were defective all the same lot.Customer stated that the end of them was curl over and were very hard.Customer also mentioned that up at the top they were shorter in the packaging, 2 inch shorter than usual.Up at the top of the catheter, the outlet part there were a large bump on it.So, insertion would be difficult because of the hard curl end.Customer request replacement for the defective product.Per follow up via pone 08jun2023, customer stated that they did not use the catheters, they saw the defect before use and wanted to inform the company of the affected lots.Per notification from investigator on 31jul2023, during sample evaluation it was found that the scratch found on the shaft close to the funnel of catheter.Per additional information received via sample form on 20jun2023, it was reported that customer opened one box and saw a defective catheter, checked the others in the box, they were all the same, so he threw that box away.Stated that the next box was fine and then they got another box of defective catheters and stated that these were shorter than they should be.The tips were curled and the hole in the tip was much further up the catheter than it should be and they ware harder and less pliable than they should be.The outlet end had a bump on the outside.Stated that they also noticed that the print on the packaging was an off color from the usual packaging and they went through all their remaining boxes, and these were the only ones, and they were all the same lot number.Stated that they would be terribly uncomfortable to use and seem like they could hurt someone if they tried to use it, and this was the remainder of two boxes and could see the flaw through the packaging.No medical intervention was reported.
 
Additional Manufacturer Narrative
The reported event was confirmed cause unknown.1 sample were confirmed to exhibit the reported failure.The device had not met specifications.The product was not used for patient treatment.The product caused the reported failure.A potential root cause for this failure mode could be ¿rough insertion-sleeve surface scratches hydrophilic coating or removes coating".The lot number is unknown; therefore, the device history record could not be reviewed.The product catalog number for this device is unknown.Therefore, bd is unable to determine the associated labeling to review.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the actual/suspected device was inspected.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERMITTENT ROCHESTER CATHETERS
Common Device Name
UNKNOWN INTERMITTENT CATHETERS
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer (Section G)
C.R. BARD INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer Contact
xeeroy rada
8195 industrial blvd
covington 30014
7707846100
MDR Report Key17595435
Report Number1018233-2023-06201
Device Sequence Number6535252
Product Code EZD
UDI-Device Identifier00801741029875
UDI-Public(01)00801741029875
Combination Product (Y/N)N
Initial Reporter StateKY
Initial Reporter CountryUS
PMA/510(K) Number
K150345
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Consumer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 11/16/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/27/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/31/2023
Supplement Date Received by Manufacturer08/24/2023
11/17/2023
Initial Report FDA Received Date08/22/2023
Supplement Report FDA Received Date08/25/2023
11/17/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-