Model Number M00539270
Medical Device Problem Codes Break (1069); Positioning Failure (1158); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/07/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Block h6: imdrf device code a0401 captures the reportable investigation result of guide catheter detached/separated.Block h10: the returned flexima biliary stent was analyzed, and a visual evaluation noted that the guide catheter was bent/kinked, stretched and was detached from the delivery system.The suture was untied, and the push catheter suture hole was torn.No other problems with the device were noted.The reported event was confirmed.Based on all the gathered information and product analysis, the failures found could have been caused by operational factors such as the deployment technique that was used at the time the stent was released, since an excess of force was applied to the device, this caused the detachment of the guide catheter from the delivery system, causing it to stretch and kink.Due to the detachment, the device loses its functionality.Therefore, adverse event related to procedure is selected as the most probable root cause for the complaint.
 
Event or Problem Description
It was reported to boston scientific that a flexima biliary stent was used during a stent placement procedure in the bile duct, performed on (b)(6) 2023.During the procedure and inside the patient, the stent could not be deployed.Another flexima biliary stent was opened and used to complete the procedure.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be stable.This event has been deemed a reportable event based on the investigation results; guide catheter detached/separated.Please see block h10 for full investigation details.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXIMA BILIARY
Common Device Name
CATHETER, BILIARY, DIAGNOSTIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
780 brookside drive
spencer IN 47460
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key17599840
Report Number3005099803-2023-04515
Device Sequence Number6308076
Product Code FGE
UDI-Device Identifier08714729162582
UDI-Public08714729162582
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K965147
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/22/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/29/2024
Device Model NumberM00539270
Device Catalogue Number3927
Device Lot Number0028118657
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/17/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date08/22/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/30/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age38 YR
Patient SexMale
Patient Weight65 KG
-
-