EXACTECH, INC. EQUINOXE REVERSE SHOULDER COMPONENTS; PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Catalog Number |
314-02-23 |
| Medical Device Problem Codes |
Unstable (1667); Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Codes |
Joint Dislocation (2374); Subluxation (4525)
|
| Date of Event |
11/19/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported by the equinoxe shoulder study that this 56 y/o male patient had a shoulder dislocation.Post op x-ray revealed shoulder was dislocated.Action taken: reduced in theatre next day.Patient was discharged in a sling on (b)(6) 2019.The case report form indicates this event is possibly related to devices and definitely related to procedure.This event report was received through clinical data collection activities.
|
| |
|
Event or Problem Description
|
|
It was reported via clinical study, that 2 days post-operatively the patient had a shoulder dislocation.Post op x-ray revealed shoulder was dislocated.The shoulder was reduced in theatre next day.Patient was discharged in a sling.Then, approximately 3 years and 13 days post-operatively, the patient experienced instability/subluxation and underwent standard reverse revision surgery in which the standard humeral stem, torque screw, and glenoid base plate were removed.The clinical report indicates that this event is possibly related to devices and/or to the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
After further review of additional information received the following sections b5, d6b, d10, g1, g3, g6, h1, h2, h3 and h6 have been updated accordingly.(d10): concomitant device(s): 300-01-11 equinoxe, humeral stem primary, press fit 11mm.300-10-15 equinoxe replicator plate 1.5mm o/s.310-01-44 equinoxe, humeral head short, 44mm (alpha).314-02-23 uhmwpe post aug glenoid medium, left.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b5, d1, d4 - removal of all, d6b, h6.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
It was reported via clinical study, that 12 days post-operatively of an initial left rtsa, the patient experienced a shoulder dislocation.Post-op x-ray revealed shoulder was dislocated.The shoulder was reduced in theatre next day and the outcome of this event is considered resolved.Patient was discharged in a sling.The clinical report indicates that this event is possibly related to devices and definitely related to the procedure.This was reported through clinical trial study data collection activities, no device return is anticipated, and no other information is available at this time.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and corrected information.The following sections were updated: h6, h11.The following sections were corrected: h6 - impact code.The reported event was unable to be confirmed due to limited information received from the customer.No device was returned for evaluation; further, photographs and/or radiograph images were not provided for review.Operative notes and/or medical records were not provided for review of usage/ technique.A review of complaint history determined that no further action is required as no trends were identified.A definitive root cause was unable to be determined; however, may have resulted from soft tissue imbalance, rotator cuff failure, patient anatomy, implant positioning, and/or implant selection.Dislocation is a known risk, as outlined in the ifu.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|