| Model Number |
ARDVST229039A |
| Medical Device Problem Code |
Peeled/Delaminated (1454)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/14/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
On (b)(6) 2023 getinge became aware of an issue with one of surgical lights - volista standop.According to the photographic evidence the label was damaged with missing particles.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination or serious injury.
|
| |
|
Additional Manufacturer Narrative
|
|
Event site name: (b)(6).Additional information will be provided following the conclusion of the investigation.H3 other text : device not returned to manufacturer.
|
| |
|
Additional Manufacturer Narrative
|
|
The correction of h3a device evaluated by manufacturer, h3b device not eval provide code, h3c if other provide code - explain fields deems required.This is based on the internal evaluation.Previous h3a device evaluated by manufacturer: no.Corrected h3a device evaluated by manufacturer: yes.Previous h3b device not eval provide code: other.Corrected h3b device not eval provide code: n/a.Previous h3c if other provide code - explain: device not returned to manufacturer.Corrected h3c if other provide code - explain: n/a.The correction of d4 catalog # and unique identifier (udi) # deems required.This is based on the internal evaluation.Previous d4 catalog # ardvst229039a.Corrected d4 catalog # blank.Previous d4 unique identifier (udi) #: n/a.Corrected d4 unique identifier (udi) #: (b)(4).The correction of d1 brand name deems required.This is based on the internal evaluation.Previous d1 brand name volista standop, corrected d1 brand name standop volista®.Getinge became aware of an issue with one of surgical lights - volista.It was stated the label was damaged with missing particles.There was no injury reported, however, we decided to report the issue in abundance of caution as any parts falling off into sterile field or during procedure may cause contamination or serious injury.As stated by the subject matter expert at the manufacturing site, label peeling is probably due to collision or repeated excessive rubbing during cleaning of the device, the use of aggressive or unsuitable cleaning agents may be a contributing factor.The user manual mentions to check the lightheads for chipped paint, impact marks and any other damages during daily checks.To prevent any incident similar to the label missing, the user manual mentions instructions concerning cleaning and disinfection, recommended and prohibited products.Getinge shall continue to monitor for any further events of this nature and does not propose any further action at this time.
|
| |
|
Event or Problem Description
|
|
Manufacturer's reference number (b)(4).
|
| |
|