Catalog Number RLT231412
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Code Aneurysm (1708)
Date of Event 03/31/2016
Type of Reportable Event Serious Injury
Event or Problem Description
On (b)(6) 2015, this patient underwent endovascular procedure to treat an abdominal aortic aneurysm using gore excluder aaa endoprostheses.Pre-treatment maximum aortic diameter was 51.2mm.From (b)(6) 2016 to (b)(6) 29, 2022 the maximum aortic diameter increased from 55mm to 66mm.Reportedly, on (b)(6) 2023, an enlargement of the juxtarenal abdominal aortic aneurysm was determined, and the patient underwent the additional procedure using an aortic endograft.The problem was solved.The patient tolerated the procedure.According to the physician, the progression of aneurysm disease caused the aneurysm enlargement.There was nothing in patient¿s anatomy caused or contributed to the event.Additionally, the physician confirmed that it was an aneurysm without endoleaks.No further adverse events have been reported.
 
Additional Manufacturer Narrative
H.6.Code c20: a review of the manufacturing records for the devices is going to be conducted.Investigation is in process.Further information will be provided.The device remains implanted and is not available for analysis.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Additional Manufacturer Narrative
H.6.Code c19: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.The device remains implanted and is not available for analysis.According to the physician, the progression of aneurysm disease caused the aneurysm enlargement.The physician confirmed that it was an aneurysm without endoleaks.According to the gore® excluder® aaa endoprosthesis instructions for use (ifu), additional considerations for patient selection include but are not limited to: patient¿s anatomical suitability for endovascular repair.According to the gore® excluder® aaa endoprosthesis instructions for use (ifu), adverse events that may occur and / or require intervention or additional intraoperative procedure time include but are not limited to aneurysm enlargement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® EXCLUDER® AAA ENDOPROSTHESIS
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL WOODY MOUNTAIN B/P
3750 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
nataliya baramzina
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key17716562
Report Number2017233-2023-04261
Device Sequence Number17825340
Product Code MIH
UDI-Device Identifier00733132622368
UDI-Public00733132622368
Combination Product (Y/N)N
Initial Reporter StateNE
Initial Reporter CountryUS
PMA/510(K) Number
P020004
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Study
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/04/2018
Device Catalogue NumberRLT231412
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/28/2023
Supplement Date Received by Manufacturer09/11/2023
Initial Report FDA Received Date09/08/2023
Supplement Report FDA Received Date09/12/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/05/2015
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Hospitalization; Required Intervention;
Patient Age71 YR
Patient SexFemale
Patient Weight62 KG
Patient RaceBlack Or African American
-
-