ABBOTT VASCULAR RX ACCULINK CAROTID STENT SYSTEM Back to Search Results
Catalog Number 1011343-30
Medical Device Problem Code Activation Failure (3270)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/16/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufacturer's investigation is still pending at this time.Results and conclusions will be provided in the final report.
 
Event or Problem Description
It was reported that the procedure was performed to treat a lesion in the internal carotid artery with mild tortuosity and 70% stenosis.The 6-8mm.014 acculink self expanding stent (ses) was introduced via right femoral approach and attempted to be deployed; however, after unlocking the handle, the stent was partially deployed.Another.014 acculink was used to complete the procedure.There were no adverse patient effects and there was no clinically significant delay in the procedure.No additional information was provided.
 
Additional Manufacturer Narrative
The device was returned for analysis.The reported activation failure was able to be confirmed.Approximately 2 millimeters (mm) of the stent was partially deployed but not flowered over the base of the tip while the rest of the stent remained inside the sheath.The handle was opened and a shaft separation distal to the slider located at the proximal end of the handle was observed.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar incidents from this lot.As there was no damage noted to the device during the inspection prior to use, the investigation determined the reported difficulties appear to be related to circumstances of the procedure as it is likely that interaction with the mildly tortuous and 70% stenosed anatomy and/or inadvertent mishandling resulted in the noted device damages (wrinkled sheath, multiple shaft bends) thus preventing the shaft lumens from moving freely resulting in the reported activation/deployment failure.Manipulation of the device in attempts to deploy the stent resulted in the noted material separation.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RX ACCULINK CAROTID STENT SYSTEM
Common Device Name
CAROTID STENT
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 2024168
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key17721275
Report Number2024168-2023-09878
Device Sequence Number20627197
Product Code NIM
UDI-Device Identifier08717648076367
UDI-Public08717648076367
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P040012
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/30/2024
Device Catalogue Number1011343-30
Device Lot Number2103161
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/05/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 08/17/2023
Supplement Date Received by Manufacturer09/19/2023
Initial Report FDA Received Date09/11/2023
Supplement Report FDA Received Date09/21/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/31/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-