| Model Number |
VLOCN0346 |
| Medical Device Problem Codes |
Break (1069); Material Frayed (1262); Unraveled Material (1664)
|
| Health Effect - Clinical Codes |
Wound Dehiscence (1154); Tissue Breakdown (2681)
|
| Date of Event |
08/02/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
According to the reporter, post-operative to an open epigastric hernia and umbilical hernia repair, patient was returned to the hospital for reoperation the next day as an emergency due to wound dehiscence.In operating room at the re-exploration, the suture layer was found to be fragmented into multiple pieces along the entire length of the wound involving both sutures.No tissue cut through of the suture was evident.The suture fragments were removed, and two lengths of suture were used for each half of the defect to close the linea alba after a ventral incisional hernia repair over a narrow mesh patch.The incision was extended more than 1 inch.The surgical time was extended 30 minutes or more due to the product problem.
|
| |
|
Search Alerts/Recalls
|
|
|