MENTOR TEXAS MENTOR MEMORYGEL BREAST IMPLANT; PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED
|
Back to Search Results |
|
| Catalog Number |
3507150MC |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Code |
Deformity/ Disfigurement (2360)
|
| Date of Event |
08/03/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Since the device has not been returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors can be made. as such, the investigation will be closed. if the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.A manufacturing record evaluation (mre) was performed, and no anomalies were found related to this complaint.In addition, the mre verifies that the device was manufactured in accordance with documented specification and procedures.Mentor is submitting this report pursuant to the provisions of 21 cfr, part 803. this report may be based on information which mentor has not been able to investigate or verify prior to the required reporting date. this report does not reflect a conclusion by fda, mentor, or its employees that the report constitutes an admission that the device, mentor, or its employees caused or contributed to the potential event described in this report. reason for device explant and/or reoperation: rupture.Manufacturer¿s reference number: (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent a primary breast augmentation surgery with 150cc mentor memorygel breast implants.Post-operatively, the patient experienced a rupture of her left prosthesis and ptosis of the right breast, which were confirmed by a medical professional.As a result, the patient underwent removal surgery without replacement on (b)(6), 2023.This report is for the left implant.Refer to manufacturing report number 1645337-2023-10974 for the contralateral event.
|
| |
|
Additional Manufacturer Narrative
|
|
On october 06, 2023, mentor received additional information.The lot number for the patient's left prosthesis was updated to 6784256.The catalog remains the same.Expiration date: 11/30/2018.Device manufacture date: 12/2/2013.A manufacturing record evaluation (mre) was performed for the updated lot number, and no anomalies were found related to this complaint.In addition, the mre verifies that the device was manufactured in accordance with documented specification and procedures.Manufacturer¿s reference number: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
On september 18, 2023, mentor received a device that matched the reported event details.On october 06, 2023, mentor confirmed that the returned device belongs to this complaint file.On october 16, 2023, mentor completed a visual inspection of the returned device.Device evaluation summary: visual analysis of the returned sample revealed that the breast implant was found to be ruptured.In addition, an area of shell abrasion was observed at the edge of the rupture.The evaluation determined that the possible cause of the rupture is consistent with normal wear.Shell abrasion suggests in-vivo folding or creasing of the device.This may be the result of the following factors: continuous and sustained stresses to the device such as too small breast pocket and folding or wrinkling of the shell in the breast pocket.In some cases, the breast implants may also wear out over time.Manufacturer¿s reference number: (b)(4).
|
| |
|