MAUDE Adverse Event Report: ROCHE DIAGNOSTICS PHOS2; PHOSPHOMOLYBDATE (COLORIMETRIC), INORGANIC PHOSPHORUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ROCHE DIAGNOSTICS PHOS2; PHOSPHOMOLYBDATE (COLORIMETRIC), INORGANIC PHOSPHORUS Back to Search Results
Catalog Number 03183793122
Medical Device Problem Codes Incorrect Measurement (1383); High Test Results (2457); Non Reproducible Results (4029)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/29/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The serial number of the customer's cobas 4000 c311 stand alone system is (b)(6).The field service engineer (fse) inspected the analyzer and determined that the sample probe had to be replaced and a special wash had to be installed.The investigation is ongoing.
 
Event or Problem Description
The initial reporter received questionable phos2 phosphate (inorganic) ver.2 results from an unspecified number of patient samples tested on the cobas 4000 c311 stand alone system.The reporter stated that there were no issues with the phosphate assay if it was run separately.However, when it was run with other assays, the results would be questionable and high.The field service representative (fsr) instructed the customer to change the cells and lamp and perform calibration and qc.The issue was not resolved.It was determined that the wash reaction part and weekly maintenance were not performed.The tasks were performed and the qc was acceptable.However, the issue with the patient results persisted.The reporter was able to provide one example of discrepant results: the initial result was 4.11 mmol/l.The repeat result was 1.03 mmol/l.
 
Additional Manufacturer Narrative
The customer did not perform the wash reaction part and a special wash had to be implemented.Product labeling states "phos2 action required special wash programming: the use of special wash steps is mandatory when certain test combinations are run together on cobas integra analyzers.Refer to the clean method sheet for further instructions and for the latest version of the extra wash cycle list.Where required, special wash/carry-over evasion programming must be implemented prior to reporting results with this test." the customer did not perform weekly maintenance.Product labeling states: "weekly maintenance perform these maintenance tasks at least once a week.In this section: cleaning the cell covers, cleaning the rinse stations, washing the reaction parts." the investigation reviewed the calibration data; the results were within specifications.The investigation noted that the results were imprecise; the results were often outside the specification of +/-3 standard deviation (sd).The field service engineer (fse) stated that the event was caused by the sample probe that had to be replaced.Product labeling states "replacing the sample probe if the sample probe is bent or otherwise damaged, you must replace it." the investigation determined the event was consistent with a preanalytic issue at the customer site (the sample probe had to be replaced).Preanalytics are within the customer's responsibility.The investigation did not identify a product problem.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PHOS2
Common Device Name
PHOSPHOMOLYBDATE (COLORIMETRIC), INORGANIC PHOSPHORUS
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
Manufacturer (Section G)
ROCHE DIAGNOSTICS GMBH
sandhofer strasse 116
mannheim (baden-wurttemberg) 68305
GM   68305
Manufacturer Contact
amy nelson
9115 hague road
indianapolis, IN 46250
MDR Report Key17798238
Report Number1823260-2023-03059
Device Sequence Number14940830
Product Code CEO
UDI-Device Identifier04015630918973
UDI-Public04015630918973
Combination Product (Y/N)Y
Initial Reporter CountryMU
PMA/510(K) Number
K951595
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2024
Device Catalogue Number03183793122
Device Lot Number70617701
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/29/2023
Supplement Date Received by Manufacturer10/05/2023
Initial Report FDA Received Date09/22/2023
Supplement Report FDA Received Date10/20/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-