| Catalog Number |
6021-3535 |
| Medical Device Problem Codes |
Degraded (1153); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Metal Related Pathology (4530)
|
| Date of Event |
08/15/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding abnormal ion level involving an unknown accolade stem was reported.The event was not confirmed.Method & results: product evaluation and results: material analysis, visual, functional and dimensional inspections could not be performed as the device was not returned.Clinician review: no medical records were received for review with a clinical consultant.Product history review: could not be performed as the device lot details were not provided.Complaint history review: could not be performed as the device lot details were not provided.Conclusions: it was reported that the patient was revised due to elevated metal ion levels.The exact cause of the event could not be determined because insufficient information was provided.Further information such as return of the device, pathology reports, pre- and post-operative x-rays and the revision operative report as well as patient history and follow-up notes are needed to complete the investigation for determining root cause.No further investigation for this event is possible at this time.If devices and/or additional information become available to indicate further evaluation is warranted, this record will be reopened.
|
| |
|
Event or Problem Description
|
|
It was reported through the filing of a lawsuit that allegedly the patient was implanted with an lfit anatomic cocr v40 femoral head on her left hip on or about (b)(6) 2013, and was revised on (b)(6) 2022.It is further alleged that the patient suffered injuries as a result of implantation and explantation of the device(s) at issue, device recall, and excessive levels of chromium and cobalt in her blood.
|
| |
|
Event or Problem Description
|
|
No new information.
|
| |
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding abnormal ion level and wear involving an accolade stem was reported.The event of wear was confirmed.Method & results: product evaluation and results: material analysis, visual, functional and dimensional inspections could not be performed as the device was not returned.Clinician review: a review with a clinical consultant indicated" this female patient underwent a primary total hip arthroplasty with cementless components in 2013 and according to the product summary developed elevated ion levels that require revision surgery in 2022.Some trunnionosis was found.I can confirm that the patient underwent the primary and revision hip arthroplasties since i was able to review the operation reports.I did not have access to any laboratory values.I cannot determine the root cause of this event with certainty.The causes of trunnionosis are multifactorial including but not limited to surgical technique, especially in the preparation and insertion of the femoral head on the trunnion.In this case the surgeon stated that he did clean and dry the trunnion.Also contributing factors can be patient factors such as activity level and bmi, and implant factors." -product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised due to elevated metal ion levels.A review with a clinical consultant indicated" this female patient underwent a primary total hip arthroplasty with cementless components in 2013 and according to the product summary developed elevated ion levels that require revision surgery in 2022.Some trunnionosis was found.I can confirm that the patient underwent the primary and revision hip arthroplasties since i was able to review the operation reports.I did not have access to any laboratory values.I cannot determine the root cause of this event with certainty.The causes of trunnionosis are multifactorial including but not limited to surgical technique, especially in the preparation and insertion of the femoral head on the trunnion.In this case the surgeon stated that he did clean and dry the trunnion.Also contributing factors can be patient factors such as activity level and bmi, and implant factors." no further investigation for this event is possible at this time.If devices and/or additional information become available to indicate further evaluation is warranted, this record will be reopened.
|
| |
|