| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
Chemical Exposure (2570)
|
| Date of Event |
09/20/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The device has not been returned to the manufacturer for evaluation.H3 other text : device not returned.
|
| |
|
Event or Problem Description
|
|
It was reported by customer that the rn noted blood leaking, confirmed that chemo tubing was secure then attempted to flush.Huber setup and noted leaking where extension tubing meets luer adapter.Additional information received 26 sep 2023 chemotherapy was infusing at the time the leak was noted where the extension tubing meets the luer connecter.Yes, treatment was interrupted while the huber needle was changed out.The needle was secured with a tegaderm dressing.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.Based on a review of this information, the following was concluded: the complaint of a leak is confirmed and was determined to be use related.One 20g x 1/2" safestep infusion set was returned for evaluation.The returned product sample was evaluated and a tear in the extension tube was seen at the interface of the proximal luer adapter.The fracture surfaces of the damage contained striation-like patterns which were indicative of flexural fatigue based failures, which may have been a contributing factor to the extension tubing damage.Repetitive mechanical stresses such as twisting and kinking may have contributed to the observed event; however, it appeared that additional unidentified factors also contributed.The device is a supplied component and the supplier has been notified of this event.This complaint will be recorded for future trending and monitoring purposes.
|
| |
|
Event or Problem Description
|
|
It was reported by customer that the rn noted blood leaking, confirmed that chemo tubing was secure then attempted to flush.Huber setup and noted leaking where extension tubing meets luer adapter.Additional information received 26 sep 2023 chemotherapy was infusing at the time the leak was noted where the extension tubing meets the luer connecter.Yes, treatment was interrupted while the huber needle was changed out.The needle was secured with a tegaderm dressing.
|
| |
|