| Catalog Number |
5955800 |
| Medical Device Problem Codes |
Defective Device (2588); Patient-Device Incompatibility (2682); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Abscess (1690); Adhesion(s) (1695); Inflammation (1932); Hernia (2240); Obstruction/Occlusion (2422); Insufficient Information (4580)
|
| Date of Event |
08/09/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st mesh on (b)(6) 2015.As reported, the patient is making a claim for an adverse patient outcome against the ventralight st mesh.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : not returned.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: h11: this supplemental emdr is submitted to document additional information provided and to correct brand name and pma/510(k) #.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-feb-2015) is considered to be a best estimate.Updated fields: a2, b3, b4, b5, b7, d4 (catalog no, lot no, expiry date, udi no), d.6b, g3, g6, h2, h4, h6, h10, h11.Corrected field: d1 (brand name) and g4 (pma/510(k) #).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st mesh on (b)(6) 2015.As reported, the patient is making a claim for an adverse patient outcome against the ventralight st mesh.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: 0on (b)(6) 2015 ¿ patient was diagnosed with large ventral hernia thereby underwent robotic repair with the implant of ventralight st using echo ps.Per operative notes, ¿the defect in periumbilical and at the site of colostomy were encountered.A circular ventralight st using echo ps was placed to cover both the defects and tacked using optifix tacker.¿ on (b)(6) 2016 ¿ patient was diagnosed with recurrent ventral incisional hernia, small bowel obstruction thereby underwent laparoscopic repair.Per operative notes, ¿adhesion to the sac was separated.The hernia defect was closed using sutures and the previous mesh was identified inferior to the defect.¿ on (b)(6) 2022 ¿ patient was diagnosed with incisional hernia, abscess secondary to mesh thereby underwent laparoscopic to open repair with the removal of mesh.Per operative notes, ¿the incisional hernia sac had multiple pockets of defect was reduced.There was a inflammatory reaction around the mesh due to pus.An abscess cavity tracked relating to mesh was removed.¿.
|
| |
|
Search Alerts/Recalls
|
|
|