Catalog Number 03666794001
Medical Device Problem Codes Display Difficult to Read (1181); Device Difficult to Setup or Prepare (1487)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/22/2023
Type of Reportable Event Malfunction
Event or Problem Description
We received an allegation of a display issue on a coaguchek xs meter.During a display check for results in the meter memory, the customer alleged the display was faded.
 
Additional Manufacturer Narrative
Section e3: occupation is patient/consumer.The meter was requested for investigation.The meter was received for investigation.The investigation is ongoing.
 
Additional Manufacturer Narrative
The investigation of the returned meter found the battery contacts and the printed circuit board (pcb) were contaminated by liquid which penetrated/corroded the solder contacts.This affects the battery contacts on the circuit board causing the issue observed by the customer.The event was due to contamination of the contacts due to improper handling or maintenance.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COAGUCHEK ® XS SYSTEM
Common Device Name
PROTHROMBIN TIME MONITOR
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
Manufacturer (Section G)
ROCHE DIAGNOSTICS GMBH
sandhofer strasse 116
mannheim (baden-wurttemberg) 68305
GM   68305
Manufacturer Contact
amy nelson
9115 hague road
indianapolis, IN 46250
MDR Report Key17966154
Report Number1823260-2023-03352
Device Sequence Number6790313
Product Code GJS
UDI-Device Identifier04015630945689
UDI-Public04015630945689
Combination Product (Y/N)Y
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
K062925
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 11/03/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number03666794001
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/17/2023
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/22/2023
Supplement Date Received by Manufacturer11/02/2023
Initial Report FDA Received Date10/19/2023
Supplement Report FDA Received Date11/03/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-