| Model Number |
980U1ENDICU |
| Medical Device Problem Codes |
Device Emits Odor (1425); No Flow (2991)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/16/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that, while in use on a patient, this 980 ventilator shut off and emitted a burning plastic smell. the patient was removed from the ventilator and placed on an alternate ventilator with no injury reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Section a: patient information cannot be provided due to the personal information protection and electronic documents act pipeda s.7(3) (c.1) h3 device evaluation summary: medtronic conducted an investigation based on all information received.It was reported that, while in use on a patient, this pb980 ventilator shut off and emitted a burning plastic smell.Review of the logs confirmed unit had loss of ventilation (lov) with a "system starting up after power failure" code.The service personnel (sp) checked the unit and found capacitor (c77) on the direct current (dc) - dc converter printed circuit board assembly (pcba) had thermal damage.To solve the issue, sp replaced the dc-dc converter pcba.Additionally sp replaced bd (breath delivery) power controller pcba as a precautionary measure.Sp also found the exhalation latch lever was very stiff and hard to open so realigned latch mechanism and solved the issue.The device passed all the required tests and calibrations as per the manufacturer's specifications at the time of service.The likely cause of the event was isolated in the field to fault in the dc-dc converter pcba.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it has met all medtronic quality specifications.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Section d9 - updated due to part return section h6 evaluation code result - additional code added component code remove g02005 and add g0201201 h3 device evaluation summary - updated due to part return medtronic conducted an investigation based on all information received.It was reported that, while in use on a patient, this pb980 ventilator shut off and emitted a burning plastic smell.Review of the logs confirmed unit had loss of ventilation (lov) with a "system starting up after power failure" code.The service personnel (sp) checked the unit and found capacitor (c77) on the direct current (dc) - dc converter printed circuit board assembly (pcba) had thermal damage.To solve the issue, sp replaced the dc-dc converter pcba.Additionally sp replaced bd (breath delivery) power controller pcba as a precautionary measure.Sp also found the exhalation latch lever was very stiff and hard to open so realigned latch mechanism and solved the issue.The device passed all the required tests and calibrations as per the manufacturer's specifications at the time of service.One bd power controller pcba was returned to medtronic for further analysis.The component was visually inspected and functionally tested with no malfunction or product deficiency observed.One dc-dc converter pcba was received for failure analysis.A visual inspection of the returned part found that capacitor c77 showed signs of damage.The dc-dc converter pcba was attached to the failure investigation test ventilator for analysis.It was confirmed using a multimeter that the capacitor was reading short at unexpected values.The analysis found that capacitor c77 failed short.If the capacitor c77 failure on the dc-dc would occur while in use on a patient, the ventilator response would be a loss of ventilation.The cause of the event was isolated to the damaged capacitor c77 in the dc-dc converter pcba.There is an existing previous internal investigation regarding this issue.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Search Alerts/Recalls
|
|
|