Model Number 15
Medical Device Problem Code Electrical Power Problem (2925)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/26/2023
Type of Reportable Event Malfunction
Event or Problem Description
The customer contacted stryker to report that their device would unexpectedly reboot during routine inspection.In this state defibrillation therapy may be delayed if needed.There was no patient involvement reported with the event.
 
Additional Manufacturer Narrative
Stryker evaluated the customer's device and was unable to duplicate the reported issue.Stryker downloaded the device's electronic records from the event for review and was able to verify the reported issue.Inspection found the battery pins had a slight deformation and were replaced.After observing proper device operation through functional and performance testing, the device was returned to the customer for use.
 
Additional Manufacturer Narrative
The initial medwatch report additional mfg narrative/h11 indicated: stryker evaluated the customer's device and was unable to duplicate the reported issue.Stryker downloaded the device's electronic records from the event for review and was able to verify the reported issue.Inspection found the battery pins had a slight deformation and were replaced.After observing proper device operation through functional and performance testing, the device was returned to the customer for use.The initial medwatch report additional mfg narrative/h11 should have indicated: stryker evaluated the customer's device and was unable to duplicate the reported issue.Stryker downloaded the device's electronic records from the event for review and was able to verify the reported issue.Inspection found the battery pins had a slight deformation and were replaced.Further inspection of the device and disassembly of the rear case found additional loose nuts on the battery pins.These were tightened to specification.After observing proper device operation through functional and performance testing, the device was returned to the customer for use.
 
Event or Problem Description
The customer contacted stryker to report that their device would unexpectedly reboot during routine inspection.In this state defibrillation therapy may be delayed if needed.There was no patient involvement reported with the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIFEPAK® 15 DEFIBRILLATOR/MONITOR
Common Device Name
AUTOMATED EXTERNAL DEFIBRILLATORS (NON-WEARABLE)
Manufacturer (Section D)
PHYSIO-CONTROL, INC. - 3015876
11811 willows road ne
redmond WA 98052
Manufacturer (Section G)
PHYSIO-CONTROL, INC. - 3015876
11811 willows road ne
redmond WA 98052
Manufacturer Contact
dara friedman
11811 willows road ne
redmond, WA 98052
4258674000
MDR Report Key17993736
Report Number0003015876-2023-01952
Device Sequence Number6726118
Product Code MKJ
UDI-Device Identifier00883873911556
UDI-Public00883873911556
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K142430
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 12/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number15
Device Catalogue Number99577-001263
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/27/2023
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 09/26/2023
Supplement Date Received by Manufacturer11/27/2023
Initial Report FDA Received Date10/24/2023
Supplement Report FDA Received Date12/01/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/23/2014
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-