| Catalog Number |
245113 |
| Medical Device Problem Code |
False Positive Result (1227)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/17/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that while using bd bbl¿ mgit¿ mycobacteria growth indicator tubes, 4ml (100/sp), there were 3 false positive results.No patient impact reported.The following information was provided by the initial reporter: "this is a complaint about suspected false positive events in three cases.The customer cultured acid-fast bacilli by the manual method.In three cases, the bacteria reacted with uv light, however it could not be confirmed on the smear.Bd have received a phone call from a client to confirm whether there have been any other similar events.
|
| |
|
Additional Manufacturer Narrative
|
|
B3: date of event is unknown.The date received by manufacturer has been used for this field.H.3.A device evaluation and/or device history review is anticipated but is not complete.Upon completion, a supplemental report will be filed.
|
| |
|
Additional Manufacturer Narrative
|
|
H.6 investigation summary material 245113 is manufactured by rehydrating the media components with usp purified water, and thoroughly mixing until a homogeneous solution is obtained.The tubes are filled, capped, torqued and then labeled by machine per standard operating procedure (sop).The tubes are terminally autoclaved in an air over pressure (aop) autoclave, per manufacturing instructions, using a validated cycle.Post autoclaving, tubes are packaged into final shipping configurations.The batch history record review for batch 3025464 was satisfactory and no quality notifications were generated during manufacturing and inspection.Filling, torquing, and autoclaving processes were within specifications.In process checks were performed at the designated intervals.As part of the release criteria for this product, the bhr was reviewed to confirm the following: -the total elapsed time between end of formulation and start of the autoclave cycle was within the specified limits.All autoclave parameters conformed to the validated cycle parameters for this product.The minimum f0 for this product was met.Retention samples from batch 3025464 (100 tubes) were available for inspection.There were zero contamination defects observed in 100/100 retention tubes from visual inspection.Retention tubes were placed into incubation to test for contamination at 20 to 25 degrees c (5 tubes) and 33 to 37 degrees c (5 tubes).At seven days incubation, no microbial growth was observed in 10/10 incubated retention tubes.The complaint history was reviewed, and one other complaint has been taken on batch 3025464 for contamination from shiga prefectural (b)(6) hospital.No return samples or photos were received for investigation of this complaint.Return samples and photos from the other complaint on this batch (complaint number (b)(4) did not confirm the complaint.This complaint cannot be confirmed.
|
| |
|
Event or Problem Description
|
|
It was reported that while using bd bbl¿ mgit¿ mycobacteria growth indicator tubes, 4ml (100/sp), there were 3 false positive results.No patient impact reported.The following information was provided by the initial reporter: "this is a complaint about suspected false positive events in three cases.The customer cultured acid-fast bacilli by the manual method.In three cases, the bacteria reacted with uv light ,however it could not be confirmed on the smear.Bd have received a phone call from a client to confirm whether there have been any other similar events.:.
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields have been updated: b5.It was reported while using bd bbl¿ mgit¿ mycobacteria growth indicator tubes, 4ml (100/sp), there was a false positive result.There was no report of patient impact.This supplemental mdr is being submitted as part of a retrospective review of records dating april 2023¿2025, under capa 11910483.
|
| |
|
Event or Problem Description
|
|
It was reported while using bd bbl¿ mgit¿ mycobacteria growth indicator tubes, 4ml (100/sp), there was a false positive result.There was no report of patient impact.
|
| |
|