• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ABBOTT MEDICAL AMPLATZER VASCULAR PLUG 4; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT MEDICAL AMPLATZER VASCULAR PLUG 4; DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION Back to Search Results
Catalog Number 9-AVP038-008
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Obstruction/Occlusion (2422)
Date of Event 10/13/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Summarized patient outcomes/complications of amplatzer vascular plug 4 were reported in a research article in a subject population with multiple co-morbidities including patent ductus arteriosus (pda), severe bronchopulmonary dysplasia (bpd) and pulmonary hypertension (ph).Some of the complications reported were obstruction/occlusion, surgical intervention, hospitalization; these complications are anticipated for the procedure and subject population.A more comprehensive assessment could not be performed as the event was non-contemporaneously reported through a literature review and no device or individual patient information was received for analysis.
 
Event or Problem Description
The article, "transcatheter closure of tubular pda with amplatzer plug 4 in preterm infants weighing between 900 and 3,400 g: the pros and cons", was reviewed.The article presented a case study of a patient born at 31 gestational weeks, weighing 2600g at time of intervention with comorbidities patent ductus arteriosus (pda), severe bronchopulmonary dysplasia (bpd) and pulmonary hypertension (ph).It was reported that on an unknown date, an 8x13.5mm amplatzer vascular plug 4 was implanted.It was later reported 3 months post-procedure on an unknown date, it was noted there was a left pulmonary artery (lpa) obstruction due to the device jailing the hypoplastic lpa.A decision was made to recanalize the obstructed lpa and a stent was implanted.The article concluded implantation of the ap4 using a 4 f 0.38 guide wire-compatible catheter without inserting a long sheath makes the closure of tubular ducts with this device feasible and uncomplicated with a short intervention time.However, the limited sizes with fixed lengths of the ap4 make it unsuitable for ducts wider than 4.5 mm and shorter than the chosen device length, which can increase the risk of significant left pulmonary stenosis.A wide range of plug diameters and lengths is required to accommodate the large and short ducts.[the primary and corresponding author was nathalie mini, department of cardiology, german paediatric heart centre, university hospital of bonn, bonn, germany, with corresponding email: nathalie.Mini@ukbonn.De].
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMPLATZER VASCULAR PLUG 4
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ABBOTT MEDICAL REG# 2135147
5050 nathan ln n
plymouth MN 55442
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key18065382
Report Number2135147-2023-04843
Device Sequence Number12702446
Product Code KRD
UDI-Device Identifier00811806012384
UDI-Public00811806012384
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K113658
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Literature,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/03/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number9-AVP038-008
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/13/2023
Initial Report FDA Received Date11/03/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient SexUnknown
Patient Weight3 KG
-
-