|
It was reported that bd alaris pump module smartsite infusion set had air in line.The following information was received by the initial reporter with the verbatim: thank so much for taking the time to talk to me today.As per our conversation: you have a generalized complaint of air-in-line with the iv set 11522558 which is the bd ball/valve set.There have been multiple internal reports (unknown number of events) of the ball failing to seat properly and air getting down into the line.There is not a lot number available for these events and there was no patient harm related to the air in line.An unknown number of these events have happened in an outpatient infusion center.Please confirm that this information regarding the reported issue of air in line from ball valve not seating properly is accurate and that there is not any other information available.On previous site visits, cpc determined that the practice in the infusion center of over programming the vtbi (volume to be infused) to include the flush was a contributing factor to the failure of the ball seating properly.A vacuum is created which can potentially prevent the ball from completely sealing the valve.If there is a deformity in the drip chamber this can also lead to the ball not seating properly.A possible solution would be to change to the short set connected to a 3 port long primary set to deliver the medications.They could include the flush as they like to, and they would intentionally run the medication to the air in line sensor.The primary line would then be used to flush the rest of the medication.I am including a link to a video that shows how this works.Response received 02 nov 2023: - are you able to provide the batch number for the defective product? in one of the event reports, this reference # was provided: reference #11522558.- how many occurrences of the defective product(s)?: i am aware of 5 reports year to date.- are you able to provide the date of the event in the format of dd-mm-yyyy?: (b)(6) 2023.- did the event involve an urgent/life threatening medical situation?: no, per the reports, no air reached the patient.- did the event cause permanent impairment of a body function? no.- did the event require medical or surgical intervention? no.- did the event cause permanent damage of a body structure? no.- any sample available for investigation? no.
|